Why the study?
The study was conducted to assess the agreement between cardiac output estimated by two-dimensional echocardiography and bioreactance methods at rest and during dobutamine stress testing in HFpEF patients.
Do bioreactance and echocardiography provide interchangeable estimates of cardiac output at rest and during dobutamine stress in HFpEF patients?
Do bioreactance and echocardiography provide interchangeable estimates of cardiac output at rest and during dobutamine stress in HFpEF patients?
Bioreactance and echocardiography provide significantly different cardiac output values during dobutamine stress in HFpEF patients and cannot be used interchangeably.
Answers are grounded in this paper and cite their sources.
Bioreactance and echocardiography yield non-interchangeable cardiac output estimates during stress in HFpEF; leaves open validation against reference standards.
Purpose To assess the agreement between cardiac output estimated by two‐dimensional echocardiography and bioreactance methods at rest and during dobutamine stress test in heart failure patients with preserved left ventricular ejection fraction (HFpEF). Methods Hemodynamic measurements were assessed in 20 stable HFpEF patients (12 females; aged 61 ± 7 years) using echocardiography and bioreactance methods during rest and dobutamine stress test at increment dosages of 5, 10, 15, and 20 μg/kg/min until maximal dose was achieved or symptoms and sign occurred, that is, chest pain, abnormal blood pressure elevation, breathlessness, ischemic changes, or arrhythmia. Results Resting cardiac output and cardiac index estimated by bioreactance and echocardiography were not significantly different. At peak dobutamine stress test, cardiac output and cardiac index estimated by echocardiography and bioreactance were significantly different (7.06 ± 1.43 vs 5.71 ± 1.59 L/min, P < .01; and 4.27 ± 0.67 vs 3.43 ± 0.87 L/m 2 /min; P < .01) due to the significant differences in stroke volume. There was a strong positive relationship between cardiac outputs obtained by the two methods at peak dobutamine stress ( r = .79, P < .01). The mean difference (lower and upper limits of agreement) between bioreactance and echocardiography cardiac outputs at rest and peak dobutamine stress was −0.45 (1.71 to −2.62) L/min and −1.35 (0.60 to −3.31) L/min, respectively. Conclusion Bioreactance and echocardiography methods provide different cardiac output values at rest and during stress thus cannot be used interchangeably. Ability to continuously monitor key hemodynamic variables such as cardiac output, stroke volume, and heart rate is the major advantage of bioreactance method.
No takes yet. Share an insight, caveat, or question.
Sengupta et al. (2020) studied this question.