Key result
Facial blood volume oscillation at 0.1 Hz travels across the face at ~3.8 mm/s.
Why the study?
Although facial blood flow oscillation around 0.1 Hz may contain key information about blood flow regulation, its origin remains unknown.
Observational (n=40)
No
Facial blood volume oscillation at 0.1 Hz exhibits slow spatial movement with an average phase velocity of 3.8 mm/s, challenging the conventional explanation that blood flow at a certain point oscillates independently of adjacent areas.
Answers are grounded in this paper and cite their sources.
Challenges independent local oscillation models in facial microcirculation; leaves open relevance to cardiovascular monitoring or physiology.
Facial blood flow, which typically exhibits distinctive oscillation at a frequency of around 0.1 Hz, has been extensively studied. Although this oscillation may include important information about blood flow regulation, its origin remains unknown. The spatial phase distribution of the oscillation is thus desirable. Therefore, we visualized facial blood volume oscillation at a frequency of around 0.1 Hz using a digital camera imaging method with an improved approximation equation, which enabled precise analysis over a large area. We observed a slow spatial movement of the 0.1-Hz oscillation. The oscillation phase was not synchronized, but instead moved slowly. The phase velocity varies with person, measurement location, and time. An average phase velocity of 3.8 mm/s was obtained for several subjects. The results are consistent with previous studies; however, the conventional explanation that the blood flow at a certain point oscillates independently of adjacent areas should be corrected. If the primary origin of the movement is myogenic activity, the movement may ascend along a blood vessel toward the upstream. Otherwise, the oscillation and its propagation can be considered to be related to Mayer waves. By determining the mechanism, some questions regarding Mayer waves can be answered. The direction of the wave (upstream or downstream) provides important information.
No takes yet. Share an insight, caveat, or question.
Yoshida et al. (2021) conducted an observational in Healthy (n=40). Digital camera imaging (DCI) was evaluated on Phase velocity of facial blood volume oscillation at 0.1 Hz. Facial blood volume oscillation at a frequency of 0.1 Hz exhibited a slow spatial movement across the face with an average phase velocity of 3.8 mm/s.
Synapse has enriched 10 related papers. Consider them for comparative context: