Why the study?
Does ECG imaging accurately reconstruct epicardial measures of repolarization dispersion noninvasively in an experimental model?
Population
Open-chest dog model and a human torso model for generating body-surface potentials
Comparison
ECG imaging method to noninvasively reconstruct… vs Direct epicardial recordings during control…
Design
Preclinical
Authors
Loading...
Should not yet change practice; leaves open clinical translation of ECG imaging for repolarization assessment.
Does ECG imaging accurately reconstruct epicardial measures of repolarization dispersion noninvasively in an experimental model?
ECG imaging can accurately reconstruct epicardial repolarization properties noninvasively, potentially enabling noninvasive risk stratification for life-threatening arrhythmias.
Ghanem et al. (2001) studied this question.