Key result
CMR-based 3D modeling identifies heterogeneous tissue channels in ~100% of swine with inducible VT.
Why the study?
Despite the potential of CMR for characterizing arrhythmogenic substrates, there was no standard approach to identify potential conduction channels.
Does CMR-based 3D structural modeling identify heterogeneous tissue channels associated with ventricular tachycardia inducibility in post-infarct swine models?
Does CMR-based 3D structural modeling identify heterogeneous tissue channels associated with ventricular tachycardia inducibility in post-infarct swine models?
Answers are grounded in this paper and cite their sources.
A novel CMR-based 3D structural modeling technique successfully identified heterogeneous tissue channels that correlate with ventricular tachycardia inducibility in a post-infarct swine model.
Geometrical structure of the myocardium plays an important role in understanding the generation of arrhythmias. In particular, a heterogeneous tissue (HT) channel defined in cardiovascular magnetic resonance (CMR) has been suggested to correlate with conduction channels defined in electroanatomic mapping in ventricular tachycardia (VT). Despite the potential of CMR for characterization of the arrhythmogenic substrate, there is currently no standard approach to identify potential conduction channels. Therefore, we sought to develop a workflow to identify HT channel based on the structural 3D modeling of the viable myocardium within areas of dense scar. We focus on macro-level HT channel detection in this work. The proposed technique was tested in high-resolution ex-vivo CMR images in 20 post-infarct swine models who underwent an electrophysiology study for VT inducibility. HT channel was detected in 15 animals with inducible VT, whereas it was only detected in 1 out of 5 animal with non-inducible VT (P < 0.01, Fisher's exact test). The HT channel detected in the non-inducible animal was shorter than those detected in animals with inducible VTs (inducible-VT animals: 35 ± 14 mm vs. non-inducible VT animal: 9.94 mm). Electrophysiology study and histopathological analyses validated the detected HT channels. The proposed technique may provide new insights for understanding the macro-level VT mechanism.
No takes yet. Share an insight, caveat, or question.
Jang et al. (2019) studied Ventricular tachycardia (n=20). CMR-based 3D structural modeling for heterogeneous tissue channel detection vs. Non-inducible VT animals was evaluated on Detection of heterogeneous tissue (HT) channel (p=<0.01). CMR-based 3D structural modeling detected heterogeneous tissue channels in 15 of 15 swine models with inducible ventricular tachycardia compared to 1 of 5 with non-inducible VT.
Synapse has enriched 10 related papers. Consider them for comparative context: