Key result
Cryoballoon PVI links to a ~15% decrease in P-wave terminal force and complexity versus baseline.
Why the study?
Cryoballoon ablation of AF alters a significant amount of myocardium, but the effect of pulmonary vein isolation on the P-wave remains unclear.
Does cryoballoon pulmonary vein isolation acutely alter signal-averaged P-wave parameters in patients with atrial fibrillation?
Observational (n=69)
Does cryoballoon pulmonary vein isolation acutely alter signal-averaged P-wave parameters in patients with atrial fibrillation?
Absolute Event Rate: 2.63% vs 3.08%
p-value: p=0.003
Cryoballoon pulmonary vein isolation acutely decreases P-wave terminal force, complexity, and sample entropy, suggesting high-resolution ECG can detect stepwise changes in atrial electrical activity during ablation.
Supports high-resolution ECG for detecting acute electrical changes during PVI; leaves open impact on clinical outcomes.
Background and aims Cryoballoon ablation of atrial fibrillation alters a significant amount of vital myocardium contributing to its electrical activity. However, the effect of pulmonary vein isolation (PVI) on the P-wave is unclear. The study aimed to quantify P-wave changes following individual PVI using signal-averaged ECG analysis. Materials and methods Unfiltered high-resolution (2,000 samples/second) ECGs were obtained for 5 min pre- and post-isolation of each pulmonary vein in 69 participants using 12 standard and 10 additional leads optimized for atrial electrical activity detection. Signal-averaged ECGs were computed and analyzed using custom software in Matlab. This study was registered at ClinicalTrials.gov (Identifier: NCT06061120). Results Significant changes in ECG parameters were found. Following complete PVI, P-wave terminal force measured in lead V1 (3.08 ± 1.99 vs. 2.63 ± 1.76 mV*ms, p = 0.003), as well as P-wave complexity (2.05 ± 0.65 vs. 1.79 ± 0.51, p < 0.001) and sample entropy (0.210 ± 0.039 vs. 0.187 ± 0.028 au, p < 0.001), both averaged across all leads, decreased significantly. Ablation of the left pulmonary veins was associated with lower values in P-wave terminal force (3.07 ± 2.05 vs. 2.84 ± 1.88 mV*ms, p = 0.003), P-wave complexity (2.02 ± 0.64 vs. 1.90 ± 0.57, p = 0.003), and sample entropy (0.210 ± 0.039 vs. 0.197 ± 0.031 au, p < 0.001) after ablation. For ablation of the right pulmonary veins, a decline was observed in sample entropy (0.196 ± 0.031 vs. 0.190 ± 0.027 au, p = 0.046). Conclusion The observed changes in signal-averaged P-wave parameters during cryoballoon PVI may indicate acute intraprocedural effects on atrial electrophysiology. These exploratory findings suggest that high-resolution, non-invasive ECG recordings are capable to detect stepwise changes of electrical atrial activity, offering new perspectives for intraprocedural assessment of ablation effects.
No takes yet. Share an insight, caveat, or question.
Fantazi et al. (2026) conducted an observational in Atrial fibrillation (n=69). Cryoballoon pulmonary vein isolation vs. Pre-isolation baseline was evaluated on P-wave terminal force in lead V1 (mV*ms) (p=0.003). Cryoballoon pulmonary vein isolation significantly decreased P-wave terminal force in lead V1 (3.08 vs. 2.63 mV*ms, p=0.003), P-wave complexity, and sample entropy compared to pre-isolation.