Key result
Sequential mapping-guided source ablation achieves 0% AF re-initiation in simulations, outperforming anatomy-based approaches.
Why the study?
PVI is the cornerstone of AF ablation but recurrences are frequent, and ablating AF sources beyond PVI may prevent re-initiations.
Does source-based ablation guided by sequential high-density mapping prevent atrial fibrillation re-initiation compared to conventional anatomy-based approaches in in silico models?
Does source-based ablation guided by sequential high-density mapping prevent atrial fibrillation re-initiation compared to conventional anatomy-based approaches in in silico models?
In an in silico computational model, targeting atrial fibrillation sources identified via repetitive conduction patterns was more effective than conventional anatomical strategies at preventing arrhythmia re-initiation.
May support source-based ablation trials in AF; leaves open translation from in silico models to patients.
AIMS: Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation, but recurrences are frequent. Ablating AF sources beyond PVI may prevent re-initiations. This proof-of-principle in silico study compares a novel source-based ablation approach to conventional strategies in preventing AF re-initiation. METHODS AND RESULTS: We compared two conventional ablation strategies [PVI and PVI + posterior wall isolation (box ablation)] with our source-based approach. After PVI, a high-density mapping catheter was guided sequentially upstream of local repetitive conduction patterns until a source was identified. Located targets were ablated, connecting them to non-conducting boundaries. Strategies were compared based on their AF re-initiation rates after incremental pacing and ablated and electrically isolated areas. Analyses were performed in seven different scenarios with atria of different sizes, without (n = 3) and with fibrosis (n = 4), to assess different AF progression stages. Compared to no ablation, PVI reduced initiation rates in non-fibrotic atria (23 ± 8% control vs. 15 ± 0% PVI) but was less effective with fibrosis (60 ± 4% vs. 53 ± 10%). Box ablation was not superior to PVI while isolating more of the left atrium (isolated area in PVI: 31.5 ± 0.7% vs. box: 43.6 ± 0.5%). Conversely, source ablation completely prevented AF initiation in all scenarios, achieving comparable left atrial isolation with box ablation (isolated area without fibrosis: 36.3 ± 1.4%; with fibrosis: 43.2 ± 2.6%) and including right atrial lesions. Although macro-re-entrant tachycardias occurred frequently after source ablation, they were terminated with minimal lesions. CONCLUSION: Ablating AF sources using our high-density mapping approach was more efficient in preventing AF re-initiation in silico than anatomy-based strategies.
No takes yet. Share an insight, caveat, or question.
Marques et al. (2025) studied Atrial fibrillation (n=7). Source-based ablation identified through sequential high-density mapping vs. Conventional ablation (PVI alone or PVI + posterior wall isolation) and no ablation was evaluated on Atrial fibrillation re-initiation rate after incremental pacing. In computer simulations, ablating AF sources identified through sequential high-density mapping completely prevented AF re-initiation (0%) across all scenarios, outperforming anatomy-based strategies.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: