Key result
Non-invasive BSM underestimates HDF by up to ~4.24 Hz versus VEGM at higher endocardial frequencies.
Why the study?
Interpreting atrial spectro-temporal parameters from body surface signals is not straightforward because these signals can be affected by torso volume conductor properties.
Does non-invasive dominant frequency estimation using body surface mapping accurately reflect invasive dominant frequency estimation in patients with persistent atrial fibrillation?
Observational (n=10)
No
Does non-invasive dominant frequency estimation using body surface mapping accurately reflect invasive dominant frequency estimation in patients with persistent atrial fibrillation?
Non-invasive dominant frequency estimation using body surface mapping shows significant differences compared to invasive measurements, highlighting the need to account for volume conductor effects in clinical interpretation.
Non-invasive mapping underestimates dominant frequency in persistent AF; challenges equivalence assumptions and leaves open accurate non-invasive applications.
Non-invasive analysis of atrial fibrillation (AF) using body surface mapping (BSM) has gained significant interest, with attempts at interpreting atrial spectro-temporal parameters from body surface signals. As these body surface signals could be affected by properties of the torso volume conductor, this interpretation is not always straightforward. This paper highlights the volume conductor effects and influences of the algorithm parameters for identifying the dominant frequency (DF) from cardiac signals collected simultaneously on the torso and atrial surface. Bi-atrial virtual electrograms (VEGMs) and BSMs were recorded simultaneously for 5 min from 10 patients undergoing ablation for persistent AF. Frequency analysis was performed on 4 s segments. DF was defined as the frequency with highest power between 4 and 10 Hz with and without applying organization index (OI) thresholds. The volume conductor effect was assessed by analyzing the highest DF (HDF) difference of each VEGM HDF against its BSM counterpart. Significant differences in HDF values between intra-cardiac and torso signals could be observed, independent of OI threshold. This difference increases with increasing endocardial HDF (BSM-VEGM median difference from -0.13 Hz for VEGM HDF at 6.25 ± 0.25 Hz to -4.24 Hz at 9.75 ± 0.25 Hz), thereby confirming the theory of the volume conductor effect in real-life situations. Applying an OI threshold strongly affected the BSM HDF area size and location and atrial HDF area location. These results suggest that volume conductor and measurement algorithm effects must be considered for appropriate clinical interpretation.
No takes yet. Share an insight, caveat, or question.
Vanheusden et al. (2018) conducted an observational in Persistent atrial fibrillation (n=10). Non-invasive body surface mapping (BSM) vs. Invasive virtual electrograms (VEGMs) was evaluated on Difference in highest dominant frequency (HDF) between BSM and VEGM. Non-invasive body surface mapping significantly underestimated the highest dominant frequency compared to invasive electrograms, with the median difference increasing from -0.13 Hz to -4.24 Hz at higher endocardial frequencies.