Key result
Harmonic phase (HARP) analysis yielded similar results to conventional homogeneous strain analysis in assessing regional strain patterns, detecting reduced maximal stretch and shortening in infarct rats.
Why the study?
Does HARP analysis accurately quantify regional myocardial wall motion and strain in small animal models of myocardial infarction compared to conventional homogeneous strain analysis?
Does HARP analysis accurately quantify regional myocardial wall motion and strain in small animal models of myocardial infarction compared to conventional homogeneous strain analysis?
HARP analysis is a valid and accurate method for automatic quantification of regional myocardial strain in small animal models.
Authors
No takes yet. Share an insight, caveat, or question.
HARP matches conventional strain analysis in rodent MI models; leaves open clinical translation pending human validation.
Liu et al. (2004) studied Myocardial infarction (n=14). Harmonic phase (HARP) analysis vs. Homogeneous strain analysis was evaluated on Regional strain patterns (maximal stretch and shortening). Harmonic phase (HARP) analysis yielded similar results to conventional homogeneous strain analysis in assessing regional strain patterns, detecting reduced maximal stretch and shortening in infarct rats.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: