Why the study?
Activation time estimation from reconstructed ECGI signals is prone to noise, over-smoothing, and inverse problem ambiguities that cause falsely homogeneous regions or artificial lines of block, requiring an understanding of the sources of these errors.
In electrocardiographic imaging, estimating activation times from transmembrane voltages provides more precise results with fewer artifacts compared to epi-endo or pericardial potentials.
May refine ECGI activation mapping; hypothesis-generating in animal simulations, clinical translation untested.
Activation times (AT) describe the sequence of cardiac depolarization and represent one of the most important parameters for analysis of cardiac electrical activity. However, estimation of ATs can be challenging due to multiple sources of noise such as fractionation or baseline wander. If ATs are estimated from signals reconstructed using electrocardiographic imaging (ECGI), additional problems can arise from over-smoothing or due to ambiguities in the inverse problem. Often, resulting AT maps show falsely homogeneous regions or artificial lines of block. As ATs are not only important clinically, but are also commonly used for evaluation of ECGI methods, it is important to understand where these errors come from. We present results from a community effort to compare methods for AT estimation on a common dataset of simulated ventricular pacings. ECGI reconstructions were performed using three different surface source models: transmembrane voltages, epi-endo potentials and pericardial potentials, all using 2nd-order Tikhonov and 6 different regularization parameters. ATs were then estimated by the community participants and compared to the ground truth. While the pacing site had the largest effect on AT correlation coefficients (CC larger for lateral than for septal pacings), there were also differences between methods and source models that were poorly reflected in CCs. Results indicate that artificial lines of block are most severe for purely temporal methods. Compared to the other source models, ATs estimated from transmembrane voltages are more precise and less prone to artifacts.
No takes yet. Share an insight, caveat, or question.
Schaufelberger et al. (2019) studied Cardiac arrhythmias. Transmembrane voltages (TMV) source model vs. Epi-endo potentials (EEP) and pericardial potentials (PP) was evaluated on Pearson correlation coefficient (CC) between estimated activation times and ground truth.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: