Key result
Optimal UFH monitoring remains undetermined due to limited APTT evidence and high anti-FXa variation.
Why the study?
What is the optimal laboratory method for therapeutic monitoring of unfractionated heparin?
What is the optimal laboratory method for therapeutic monitoring of unfractionated heparin?
The optimal laboratory test for monitoring unfractionated heparin remains undetermined due to limitations and inter-laboratory variation in both APTT and anti-FXa assays.
Supports cautious interpretation of APTT and anti-FXa for UFH; leaves open need for standardized assays.
INTRODUCTION: Heparin is one of the oldest biological medicines with an established role in prevention and treatment of arterial and venous thromboembolism. Published therapeutic ranges for unfractionated heparin (UFH) mostly precede the large increase in the number of activated partial thromboplastin time (APTT) reagent/instrument combinations that now show wide variability. Areas covered: This paper explores the use of UFH, the development of heparin therapeutic ranges (HTRs), and the strengths and limitations of the methods used to monitor heparin's anticoagulant effect. Expert commentary: Despite longstanding use of UFH for management of thromboembolic conditions, the optimal test for monitoring UFH remains undetermined. Although used extensively for monitoring UFH, routine APTT-derived HTRs are based on limited science that may have little relevance to current laboratory practice. Anti-FXa levels may provide better and more reliable HTRs; however, even these levels show considerable inter-laboratory variation, and there are insufficient clinical studies proving improved clinical efficacy. Alternative tests for monitoring UFH reported over time have not been proven effective nor feasible, secondary to technical or cost issues, or lack of general adoption. Thus, despite limited evidence of clinical utility, an uncomfortable marriage of convenience represented by heparin laboratory monitoring is unlikely to be terminated in the immediate future.
No takes yet. Share an insight, caveat, or question.
Baluwala et al. (2017) conducted a review in Arterial and venous thromboembolism. Therapeutic monitoring of unfractionated heparin (APTT and Anti-FXa) was evaluated. The optimal test for monitoring unfractionated heparin remains undetermined, as routine APTT ranges are based on limited science and anti-FXa levels show considerable inter-laboratory variation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: