Key result
Automated T1 map thresholding in swine with ICDs yields ~83% dense scar alignment with synthetic LGE.
Why the study?
Post-contrast mapping showed promise for automated scar segmentation in subjects without ICDs, but had not been implemented in patients with ICDs.
Does automated cluster-based thresholding of post-contrast T1 maps enable accurate scar segmentation in a swine model of ischemic heart disease with ICDs compared to standard LGE without ICDs?
Does automated cluster-based thresholding of post-contrast T1 maps enable accurate scar segmentation in a swine model of ischemic heart disease with ICDs compared to standard LGE without ICDs?
Automated cluster-based thresholding of post-contrast T1 maps provides a reproducible approach to myocardial scar segmentation in the presence of ICDs, with high volumetric accuracy and Dice similarity to standard LGE.
Answers are grounded in this paper and cite their sources.
May enable ICD-compatible scar mapping in preclinical models; leaves open human validation before clinical use.
Purpose Post‐contrast mapping has proven promising for automated scar segmentation in subjects without ICDs, but this has not been implemented in patients with ICDs. We introduce an automated cluster‐based thresholding method for maps with an ICD present and compare it to manually tuned thresholding of synthetic LGE images with an ICD present and standard LGE without an ICD present. Methods Seven swine received an ischemia‐reperfusion myocardial infarction and were imaged at 3 T 4–5 weeks post‐infarct with and without an ICD. Mapping‐based thresholding was performed using synthetic LGE and artifact‐corrected cluster‐thresholding methods, both employing connected component filtering. Standard pixel signal intensity thresholding was performed on the conventional LGE without an ICD. Volumetric accuracy is relative to conventional LGE and Dice similarity between SynLGE and cluster‐based segmentations were evaluated. Results No statistical significance was observed between LGE volumes without an ICD and both SynLGE and artifact‐corrected cluster‐threshold volumes with an ICD, when using connected component filtering. Additionally, Dice alignment between SynLGE and cluster‐thresholding was high for healthy myocardium (0.96), dense scar (0.83), and dense scar union gray zone (0.91) when artifact correction and connected component filtering were implemented. Conclusion Clustering of maps holds promise for a reproducible approach to scar segmentation in the presence of ICDs.
No takes yet. Share an insight, caveat, or question.
Sheagren et al. (2025) studied Ischemic heart disease (n=7). Automated cluster-based thresholding of T1 maps vs. Standard LGE without an ICD and synthetic LGE with an ICD was evaluated on Volumetric accuracy relative to conventional LGE and Dice similarity. Automated cluster-based thresholding of T1 maps in swine with ICDs yielded high Dice alignment with synthetic LGE for healthy myocardium and dense scar.
Synapse has enriched 10 related papers. Consider them for comparative context: