Key result
Wideband motion-corrected LGE MRI shows lower specificity for heterogeneous tissue corridors versus conventional LGE.
Why the study?
Catheter ablation targets scar regions causing VT, but the performance of wideband motion-corrected LGE in identifying arrhythmia substrate in the presence of an ICD required evaluation against conventional LGE without an ICD.
Does 2-dimensional wideband motion-corrected LGE MRI with an ICD present improve the identification of physiologically relevant heterogeneous tissue corridors compared to conventional LGE without an ICD in infarcted Yorkshire swine?
Does 2-dimensional wideband motion-corrected LGE MRI with an ICD present improve the identification of physiologically relevant heterogeneous tissue corridors compared to conventional LGE without an ICD in infarcted Yorkshire swine?
Wideband motion-corrected LGE MRI in the presence of an ICD demonstrated reduced specificity for identifying physiologically relevant arrhythmia substrates compared to conventional LGE without an ICD in a swine infarct model.
Reduced specificity of wideband motion-corrected LGE in ICD swine models warrants caution in substrate mapping; leaves open refinements for clinical validation.
Background: Sudden cardiac death is a leading worldwide cause of cardiac mortality and is largely related to ventricular tachycardia (VT) in patients with known myocardial scarring. In these patients, implantable cardioverter-defibrillator (ICD) therapy reduces arrhythmia-related mortality. However, curative procedures such as catheter ablation are used to homogenize regions of scar and remove structural re-entry circuits that cause VT. Objective: In this paper, we conduct a preliminary experiment comparing 2-dimensional (2D) late gadolinium enhancement (LGE) and 3-dimensional (3D) LGE without an ICD with wideband motion-corrected (WB-MOCO) LGE with an ICD in a cohort of infarcted Yorkshire swine. Methods: Animals were imaged after infarct with conventional 2D and 3D LGE without an ICD present and 2D WB-MOCO LGE with an ICD present. Images were analyzed to determine heterogeneous tissue corridor (HTC) count and location, which were compared with circuit exit locations determined using a 12-lead electrocardiogram. Results: We found a statistically significant increase in HTC count with WB-MOCO LGE, but no significant differences in the number of true-positive or false-positive HTCs per subject. Conclusion: WB-MOCO LGE has reduced specificity to physiologically relevant HTCs than conventional 2D or 3D LGE.
No takes yet. Share an insight, caveat, or question.
Sheagren et al. (2025) studied this question. Wideband motion-corrected late gadolinium enhancement MRI showed reduced specificity for physiologically relevant heterogeneous tissue corridors compared to conventional 2D or 3D LGE.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: