Key result
Direct His bundle pacing allowed determination of His-Purkinje system refractoriness when unobtainable by atrial pacing, though clinical usefulness is limited by a low success rate (1 of 60 patients).
Why the study?
Does His bundle pacing allow for the determination of His-Purkinje refractoriness compared to atrial pacing?
Case Report (n=60)
Does His bundle pacing allow for the determination of His-Purkinje refractoriness compared to atrial pacing?
Direct His bundle pacing can determine His-Purkinje system refractoriness when atrial pacing fails, but its clinical utility is limited by a very low procedural success rate.
Answers are grounded in this paper and cite their sources.
May enable His-Purkinje refractoriness assessment when atrial pacing fails; leaves open clinical utility given low success in case reports.
Consistent His bundle pacing was accomplished in one of 60 consecutive patients. Intracardiac electrophysiologic studies in this patient revealed rapid atrioventricular nodal conduction (AH = 55 msec). While the relative refractory period of the His-Purkinje system as a whole determined by His bundle pacing (using the extrastimulus technique) was identical to that determined by atrial pacing, changes in right bundle branch refractoriness differed. An atrial extrasystolic interval of 370 msec resulted in right bundle branch block, whereas direct His pacing at a shorter extrasystolic interval (360 msec) failed to produce a bundle branch block pattern. The effective refractory period of the His-Purkinje system could not be determined by atrial pacing because of atrial refractoriness, but was obtained by His bundle pacing. Theoretically, direct His bundle pacing may be of value in determining His-Purkinje system refractoriness when this parameter is unobtainable due to either atrial or atrioventricular nodal refractoriness. This technique appears to have limited clinical usefulness, however, because of the very small success rates. Finally, His-Purkinje system refractoriness may differ, depending on site of stimulation, presumably due to differing inputs into the His-Purkinje system.
No takes yet. Share an insight, caveat, or question.
Peters et al. (1979) reported a case report. His bundle pacing vs. Atrial pacing was evaluated on His-Purkinje system refractoriness. Direct His bundle pacing allowed determination of His-Purkinje system refractoriness when unobtainable by atrial pacing, though clinical usefulness is limited by a low success rate (1 of 60 patients).