Answers are grounded in this paper and cite their sources.
Human skin displays complex viscoelastic behavior arising from the interplay of collagen, elastin, and dermal ground substances, yet existing suction- and indentation-based devices provide limited physiological relevance and insufficient temporal resolution to characterize dynamic mechanical responses. We developed a novel contact-based elasticity device that applies controlled mechanical micro-compression using a rotary actuator and quantifies deformation through time-resolved electrical resistance sensing. A fully automated algorithm segments the resulting time-series into repeated base–peak–trough cycles and extracts multi-dimensional biomechanical descriptors, including deformation amplitude, loading slope, snap-back velocity, recovery time, and energy-based metrics. Validation with PDMS standards confirmed that five of six parameters robustly distinguished materials of different stiffness, demonstrating high sensitivity across a broad elasticity range. In individual measurements revealed clear lateral asymmetry within a single individual: the right cheek exhibited greater deformation and steeper loading slopes, whereas the left cheek showed faster recovery kinetics. A total of 250 participants aged 16–80 years were enrolled, including 218 female and 32 male participants, five viscoelastic parameters exhibited significant positive correlations with age (r = 0.16–0.33), revealing age-dependent degradation patterns that were not detectable in raw data. These findings demonstrate that integrating controlled compression with high-frequency resistance sensing enables detailed, physiologically relevant quantification of skin mechanics beyond the capabilities of traditional suction devices. The device algorithm system offers a robust platform for dermatologic evaluation, cosmetic efficacy testing, population-level aging research, and next-generation personalized skin-profiling technologies. • Rotary-actuated device measures skin mechanics via high-frequency resistance sensing • Automated algorithm extracts multi-cycle deformation and recovery features • PDMS and silicone phantoms validate five mechanical parameters across stiffness range • In vivo tests reveal cheek asymmetry in stiffness and viscoelastic recovery behavior • IQR filtering reduces 250 subjects to 199 high-quality datasets, strengthening age trends
No takes yet. Share an insight, caveat, or question.
Ahn et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: