Key result
Lower baseline LVEF predicts cardiac immune-related adverse events during immune checkpoint inhibitor therapy.
Why the study?
ICIs can cause cardiac immune-related adverse events, and early identification of at-risk patients is crucial; echocardiographic parameters may serve as valuable predictors in Japanese patients receiving ICI therapy.
Do baseline echocardiographic parameters predict cardiac immune-related adverse events in patients receiving immune checkpoint inhibitor therapy?
Observational (n=73)
No
Do baseline echocardiographic parameters predict cardiac immune-related adverse events in patients receiving immune checkpoint inhibitor therapy?
Baseline echocardiographic parameters, particularly lower ejection fraction and larger left ventricular end-systolic diameter, can help predict the risk of cardiac immune-related adverse events in patients starting immune checkpoint inhibitor therapy.
Answers are grounded in this paper and cite their sources.
Baseline LVEF assessment may aid pre-ICI risk stratification; leaves open whether screening improves outcomes in prospective cohorts.
Background Immune checkpoint inhibitors (ICIs) have transformed cancer treatment but are associated with immune-related adverse events, including cardiac immune-related adverse events (cardiac irAEs). Early identification of patients at risk for cardiac irAEs is crucial, and echocardiographic parameters may serve as valuable predictors. This study aimed to evaluate the predictive utility of echocardiographic indices in assessing cardiac irAE risk in Japanese patients receiving ICI therapy. Methods This retrospective study analyzed patients treated with ICIs at the University of Fukui Hospital between November 2015 and October 2018. Cardiac irAEs were defined according to the ESC guidelines. Results Among 73 patients, six (8%) developed cardiac irAEs, with no fatalities. Echocardiographic assessment before ICI initiation revealed that patients who later developed cardiac irAEs had significantly lower ejection fractions (EFs) ( p < 0.05). Receiver operating characteristic analysis demonstrated that left ventricular end-systolic diameters (LVDs) (area under the curve: AUC = 0.660) and EFs (AUC = 0.797) had moderate predictive value for cardiac irAEs. Kaplan–Meier analysis showed a higher probability of cardiac irAEs in patients with LVDs and EFs beyond specific thresholds ( p < 0.01). Poisson regression analysis indicated a decreasing risk of cardiac irAEs over time after ICI initiation. Conclusion Baseline echocardiographic parameters, particularly LVDs and EFs, can be useful predictors of cardiac irAEs in patients receiving ICI therapy. Early echocardiographic evaluation may facilitate risk stratification and improve monitoring strategies for cardiac irAEs . Clinical trial registration number UMIN000023840.
No takes yet. Share an insight, caveat, or question.
Yamaguchi et al. (2025) conducted an observational in Cancer requiring immune checkpoint inhibitor therapy (n=73). Immune checkpoint inhibitors (ICIs) vs. Patients without cardiac immune-related adverse events was evaluated on Baseline left ventricular ejection fraction (EF) predicting cardiac immune-related adverse events (AUC 0.80, 95% CI 0.52-1.0, p=<0.01). Baseline lower left ventricular ejection fraction significantly predicted the development of cardiac immune-related adverse events in patients receiving immune checkpoint inhibitor therapy.
Synapse has enriched 10 related papers. Consider them for comparative context: