Key result
Late diastolic vortex rings sit closer to the mitral annulus and are more elliptical than early rings.
Why the study?
Does retrospectively-gated 4D Flow CMR allow for quantitative characterization of 3D vortex rings during early and late left ventricular filling in healthy subjects?
Population
24 healthy volunteers, mean age 20±10 years.
Design
Cross-sectional
Authors
Loading...
Retrospectively-gated 4D Flow CMR enables LV vortex characterization in normals; leaves open clinical translation and validation in disease.
Observational (n=24)
No
Does retrospectively-gated 4D Flow CMR allow for quantitative characterization of 3D vortex rings during early and late left ventricular filling in healthy subjects?
Absolute Event Rate: 0.19% vs 0.15%
p-value: p=0.0001
Retrospectively-gated 4D Flow CMR is feasible for quantitatively characterizing 3D vortex rings in LV inflow, demonstrating distinct differences between early and late diastolic phases in normal subjects.
Elbaz et al. (2014) conducted an observational in Healthy (n=24). Early diastolic filling (E-vortex) vs. Late diastolic filling (A-vortex) was evaluated on Longitudinal position (L) of vortex ring core (p=0.0001). In normal subjects, late diastolic left ventricular vortex rings were significantly closer to the mitral valve annulus (L=0.15 vs 0.19) and more elliptical than early diastolic vortex rings.