Key result
Late diastolic vortex rings sit closer to the mitral annulus and are more elliptical than early rings.
Why the study?
Does retrospectively-gated 4D Flow CMR allow for quantitative characterization of 3D vortex rings during early and late left ventricular filling in healthy subjects?
Observational (n=24)
No
Does retrospectively-gated 4D Flow CMR allow for quantitative characterization of 3D vortex rings during early and late left ventricular filling in healthy subjects?
Retrospectively-gated 4D Flow CMR is feasible for quantitatively characterizing 3D vortex rings in LV inflow, demonstrating distinct differences between early and late diastolic phases in normal subjects.
Answers are grounded in this paper and cite their sources.
Retrospectively-gated 4D Flow CMR enables LV vortex characterization in normals; leaves open clinical translation and validation in disease.
BACKGROUND: LV diastolic vortex formation has been suggested to critically contribute to efficient blood pumping function, while altered vortex formation has been associated with LV pathologies. Therefore, quantitative characterization of vortex flow might provide a novel objective tool for evaluating LV function. The objectives of this study were 1) assess feasibility of vortex flow analysis during both early and late diastolic filling in vivo in normal subjects using 4D Flow cardiovascular magnetic resonance (CMR) with retrospective cardiac gating and 3D vortex core analysis 2) establish normal quantitative parameters characterizing 3D LV vortex flow during both early and late ventricular filling in normal subjects. METHODS: With full ethical approval, twenty-four healthy volunteers (mean age: 20±10 years) underwent whole-heart 4D Flow CMR. The Lambda2-method was used to extract 3D LV vortex ring cores from the blood flow velocity field during early (E) and late (A) diastolic filling. The 3D location of the center of vortex ring core was characterized using cylindrical cardiac coordinates (Circumferential, Longitudinal (L), Radial (R)). Comparison between E and A filling was done with a paired T-test. The orientation of the vortex ring core was measured and the ring shape was quantified by the circularity index (CI). Finally, the Spearman's correlation between the shapes of mitral inflow pattern and formed vortex ring cores was tested. RESULTS: Distinct E- and A-vortex ring cores were observed with centers of A-vortex rings significantly closer to the mitral valve annulus (E-vortex L=0.19±0.04 versus A-vortex L=0.15±0.05; p=0.0001), closer to the ventricle's long-axis (E-vortex: R=0.27±0.07, A-vortex: R=0.20±0.09, p=0.048) and more elliptical in shape (E-vortex: CI=0.79±0.09, A-vortex: CI=0.57±0.06; <0.001) compared to E-vortex. The circumferential location and orientation relative to LV long-axis for both E- and A-vortex ring cores were similar. Good to strong correlation was found between vortex shape and mitral inflow shape through both the annulus (r=0.66) and leaflet tips (r=0.83). CONCLUSIONS: Quantitative characterization and comparison of 3D vortex rings in LV inflow during both early and late diastolic phases is feasible in normal subjects using retrospectively-gated 4D Flow CMR, with distinct differences between early and late diastolic vortex rings.
No takes yet. Share an insight, caveat, or question.
Elbaz et al. (2014) conducted an observational in Healthy (n=24). Early diastolic filling (E-vortex) vs. Late diastolic filling (A-vortex) was evaluated on Longitudinal position (L) of vortex ring core (p=0.0001). In normal subjects, late diastolic left ventricular vortex rings were closer to the mitral valve annulus and more elliptical than early diastolic vortex rings.