Why the study?
Does warfarin anticoagulation increase procedural and 30-day complications in patients undergoing outpatient ICD surgery?
Does warfarin anticoagulation increase procedural and 30-day complications in patients undergoing outpatient ICD surgery?
Outpatient ICD surgery on warfarin anticoagulation has a similar overall 30-day complication rate to surgery off warfarin, but is associated with a significantly higher risk of pocket hematoma.
Answers are grounded in this paper and cite their sources.
Similar overall complications but higher pocket hematoma with warfarin; leaves open optimal periprocedural anticoagulation strategy.
BACKGROUND: Implantable cardioverter defibrillator (ICD) implantation is being performed differently at many hospitals, with some keeping patients overnight after procedure while others discharge patients home same day. In addition, many centers are now performing ICD surgery while on warfarin anticoagulation. There are, however, limited data on outpatient ICD surgery on anticoagulated (AC) patients. OBJECTIVE: We wished to evaluate the safety of performing outpatient ICD surgery with and without warfarin anticoagulation. METHODS: We evaluated 866 patients who underwent outpatient ICD surgery between April 2010 and September 2014. Patients who were on novel oral anticoagulants, or did not have an international normalized ratio drawn within 24 hours of the procedure were excluded and the remainder were divided into two groups based on whether they were on (n = 230) or off (n = 518) warfarin anticoagulation. We evaluated both procedural and 30-day complications in both groups. RESULTS: The complication rate at 30 days in the warfarin AC group was 4.3%, while in the nonanticoagulated (NAC) group was 2.9% and not significantly different (P = 0.31). However, the pocket hematoma rate in the warfarin anticoagulated group was 3.5%, as compared to the NAC group that was 0.4% (P = 0.001). CONCLUSION: Complications from ICD surgery are low in the ambulatory setting on or off warfarin anticoagulation and appear to be comparable. However, warfarin use during ICD surgery is associated with an increased risk of pocket hematoma.
No takes yet. Share an insight, caveat, or question.
Tolat et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: