Key result
Delta V6 R-wave peak time >12 ms detects lack of His capture with 100% sensitivity.
Why the study?
During nonselective His bundle pacing, it is clinically important to confirm His bundle capture versus right ventricular septal capture.
Does delta V6 RWPT > 12 ms accurately diagnose lack of His bundle capture in patients with permanent His bundle pacing?
Observational (n=219)
Blinded observer
Does delta V6 RWPT > 12 ms accurately diagnose lack of His bundle capture in patients with permanent His bundle pacing?
A novel ECG criterion using delta V6 R-wave peak time > 12 ms accurately differentiates His bundle capture from right ventricular septal capture.
Answers are grounded in this paper and cite their sources.
Delta V6 RWPT >12 ms may aid ECG confirmation of His bundle capture; hypothesis-generating and requires prospective validation.
Background During nonselective His bundle (HB) pacing, it is clinically important to confirm His bundle capture versus right ventricular septal (RVS) capture. The present study aimed to validate the hypothesis that during HB capture, left ventricular lateral wall activation time, approximated by the V 6 R‐wave peak time (V 6 RWPT), will not be longer than the corresponding activation time during native conduction. Methods Consecutive patients with permanent HB pacing were recruited; cases with abnormal His‐ventricle interval or left bundle branch block were excluded. Two corresponding intervals were compared: stimulus‐V 6 RWPT and native HB potential‐V 6 RWPT. The difference between these two intervals (delta V 6 RWPT), which was diagnostic of lack of HB capture, was identified using receiver operating characteristic (ROC) curve analysis. Results A total of 723 electrocardiograms (ECGs) (219 with native rhythm, 172 with selective HB, 215 with nonselective HB, and 117 with RVS capture) were obtained from 219 patients. The native HB‐V 6 RWPT, nonselective‐, and selective‐HB paced V 6 RWPT were nearly equal, while RVS V 6 RWPT was 32.0 (±9.5) ms longer. The ROC curve analysis indicated delta V 6 RWPT > 12 ms as diagnostic of lack of HB capture (specificity of 99.1% and sensitivity of 100%). A blinded observer correctly diagnosed 96.7% (321/332) of ECGs using this criterion. Conclusions We validated a novel criterion for HB capture that is based on the physiological left ventricular activation time as an individualized reference. HB capture can be diagnosed when paced V 6 RWPT does not exceed the value obtained during native conduction by more than 12 ms, while longer paced V 6 RWPT indicates RVS capture.
No takes yet. Share an insight, caveat, or question.
Jastrzębski et al. (2021) conducted an observational in Permanent His bundle pacing (n=219). Delta V6 R-wave peak time (V6 RWPT) criterion vs. Native conduction was evaluated on Diagnosis of lack of His bundle capture. A delta V6 R-wave peak time > 12 ms compared to native conduction accurately diagnosed lack of His bundle capture with 100% sensitivity and 99.1% specificity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: