Key result
Current of injury during LBBP is linked to 100% low-threshold LBB capture.
Why the study?
Left bundle branch pacing is a novel physiological pacing option, but the impact of left bundle branch current of injury had not been evaluated.
Does the presence of left bundle branch current of injury (COI) during left bundle branch pacing (LBBP) affect pacing parameters and safety in patients with QRS < 120 ms?
Observational (n=115)
Does the presence of left bundle branch current of injury (COI) during left bundle branch pacing (LBBP) affect pacing parameters and safety in patients with QRS < 120 ms?
Answers are grounded in this paper and cite their sources.
The presence of left bundle branch current of injury during LBBP is associated with low capture thresholds and selective LBB capture without increasing complications.
BACKGROUND: Left bundle branch pacing (LBBP) is emerging as a novel option for physiological ventricular pacing. The impact of current of injury (COI) at left bundle branch (LBB) has not been previously evaluated. METHODS: Consecutive patients with QRS duration less than 120 milliseconds referred for LBBP in whom LBB potentials were recorded were included from August 2018 to March 2019. We recorded LBB COI during LBBP and assessed its impact on the pacing parameters and complications during implantation and at short term follow-up. RESULTS: A total of 115 patients with an identifiable LBB potential at implant were included. LBB COI was confirmed in 77 (67.0%) of these patients. Three types of LBB COI were observed. LBB was captured in all patients at a pacing threshold less than 1.5 V/0.5 ms in COI(+) patients, while present in only 29 patients without an LBB COI(-) (100% vs 76.3%; P < .001). There was no significant difference between COI(+) and COI(-) patients in LBB bundle capture threshold (0.64 ± 0.24 vs 0.74 ± 0.26 V/0.5 ms). Selective LBBP was more common in COI(+) group than COI(-) group (54.5% vs 0%; P < .001). Pacing parameters were stable and no lead perforation or dislodgements were observed during follow-up. CONCLUSIONS: LBB COI is commonly observed during LBBP in cases with an identifiable LBB potential and can be associated with a low LBB capture threshold and demonstrable selective capture of the LBB acutely and during follow-up. A COI does not preclude safe and stable LBBP pacing.
No takes yet. Share an insight, caveat, or question.
Su et al. (2020) conducted an observational in Patients referred for left bundle branch pacing (n=115). Left bundle branch pacing with current of injury (COI+) vs. Left bundle branch pacing without current of injury (COI-) was evaluated on LBB capture at a pacing threshold less than 1.5 V/0.5 ms (p=<.001). Left bundle branch current of injury during LBBP was associated with a higher rate of LBB capture at a threshold <1.5 V/0.5 ms compared to patients without COI.
Synapse has enriched 10 related papers. Consider them for comparative context: