The radarODE deep learning model improved contactless ECG reconstruction from millimeter-wave radar compared to benchmarks, with improvements of 9%, 16%, and 19% in missed detection rate, RMSE, and Pearson correlation.
A novel ODE-embedded deep learning model (radarODE) improves the fidelity of contactless ECG reconstruction from millimeter-wave radar signals.
Effect estimate: improvements of 9%, 16% and 19%
Radar-based cardiac monitoring has become a popular research direction recently, but the fine-grained electrocardiogram (ECG) signal is still hard to reconstruct from millimeter-wave radar signal. The key obstacle is to decouple cardiac activities in the electrical domain (i.e., ECG) from that in the mechanical domain (i.e., heartbeat), and most existing research only uses purely data-driven methods to map such domain transformation as a black box. Therefore, this work first proposes a signal model that considers the fine-grained cardiac feature sensed by radar, and a novel deep learning framework called radarODE is designed to extract both temporal and morphological features for generating ECG. In addition, ordinary differential equations are embedded in radarODE as a decoder to provide morphological prior, helping the convergence of the model training and improving the robustness under body movements. After being validated on the dataset, the proposed radarODE achieves better performance compared with the benchmark in terms of missed detection rate, root mean square error, Pearson correlation coefficient with improvements of 9%, 16% and 19%, respectively. The validation results imply that radarODE is capable of recovering ECG signals from radar signals with high fidelity and can potentially be implemented in real-life scenarios
Zhang et al. (Wed,) conducted a other in Cardiac monitoring / ECG reconstruction. radarODE (ODE-Embedded Deep Learning Model) vs. benchmark methods was evaluated on missed detection rate, root mean square error, and Pearson correlation coefficient (improvements of 9%, 16% and 19%). The radarODE deep learning model improved contactless ECG reconstruction from millimeter-wave radar compared to benchmarks, with improvements of 9%, 16%, and 19% in missed detection rate, RMSE, and Pearson correlation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: