Key result
Speckle-tracking echocardiography establishes normal LV mechanical synchrony ranges in healthy cats with ~13% circumferential heterogeneity.
Why the study?
What are the normal ranges of left ventricular mechanical heterogeneity and synchrony in clinically healthy cats assessed by two-dimensional speckle-tracking echocardiography?
Cross-Sectional (n=34)
What are the normal ranges of left ventricular mechanical heterogeneity and synchrony in clinically healthy cats assessed by two-dimensional speckle-tracking echocardiography?
This study establishes normal reference ranges for left ventricular mechanical heterogeneity and synchrony in healthy cats using two-dimensional speckle-tracking echocardiography.
Answers are grounded in this paper and cite their sources.
Offers reference values for feline LV synchrony; leaves open validation in disease before clinical use.
Ventricular heterogeneity and synchrony are associated with hypertrophic cardiomyopathy in humans. Hypertrophic cardiomyopathy is commonly observed in cats. The aim of this study was to determine the presence and normal range of left ventricular mechanical heterogeneity and synchrony in clinically healthy cats using two-dimensional speckle-tracking echocardiography. Thirty-four clinically healthy cats were included in this prospective study. Two-dimensional echocardiography and two-dimensional speckle-tracking echocardiography were performed on all cats. Echocardiographic parameters, including circumferential, radial, and longitudinal strain and strain rate, heterogeneity, and synchrony, were measured. Segmental heterogeneity values in the circumferential, radial, and longitudinal directions were 13.1%±5.9%, 19.1%±10.3%, and 15.4%±6.8%, respectively. Transmural heterogeneity was -14.3%±4.6% in the circumferential direction. Left ventricular synchrony values in the circumferential, radial, and longitudinal directions were 11.7±4.2, 16.5±13.4, and 19.4±8.5 ms, respectively. Inter-ventricular synchrony was -3.9±13.2 ms. Left ventricular heterogeneity and synchrony were noted in clinically healthy cats; segmental heterogeneity, which is characterized as longitudinal, progressively increased from the apical to the basal segments, while transmural heterogeneity, which is characterized as circumferential, progressively decreased from the endocardium to the epicardium.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2016) conducted a cross-sectional in Clinically healthy cats (n=34). Two-dimensional speckle-tracking echocardiography was evaluated on Presence and normal range of left ventricular mechanical heterogeneity and synchrony. Two-dimensional speckle-tracking echocardiography established normal ranges for left ventricular mechanical synchrony in healthy cats, with circumferential segmental heterogeneity at 13.1%±5.9%.
Synapse has enriched 10 related papers. Consider them for comparative context: