PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 1, 2017Circulation Arrhythmia and Electrophysiology66 citations

Resolving Bipolar Electrogram Voltages During Atrial Fibrillation Using Omnipolar Mapping

View Full Paper
SHShouvik HaldarKMKarl MagtibayAPAndreu Porta‐Sánchez

Structured PICO

Does omnipolar mapping extract higher maximal voltages from AF signals compared to bipolar mapping in a canine model?

P
Population
Dogs with a high-density fixed multielectrode plaque placed on the epicardial surface of the left atrium
I
Intervention
Omnipolar electrogram mapping (V max)
C
Comparator
Bipolar electrogram mapping (horizontal and vertical orientation, V pp)
O
Outcome
Peak-to-peak voltages in sinus rhythm (SR) and atrial fibrillation (AF)surrogate

Omnipolar mapping can extract maximal voltages from AF signals unaffected by directional factors, collision, or fractionation, overcoming limitations of contemporary bipolar techniques.

Abstract

Background: Low-voltage–guided substrate modification is an emerging strategy in atrial fibrillation (AF) ablation. A major limitation to contemporary bipolar electrogram (EGM) analysis in AF is the resultant lower peak-to-peak voltage (V pp ) from variations in wavefront direction relative to electrode orientation and from fractionation and collision events. We aim to compare bipole V pp with novel omnipolar peak-to-peak voltages (V max ) in sinus rhythm (SR) and AF. Methods and Results: A high-density fixed multielectrode plaque was placed on the epicardial surface of the left atrium in dogs. Horizontal and vertical orientation bipolar EGMs, followed by omnipolar EGMs, were obtained and compared in both SR and AF. Bipole orientation has significant impact on bipolar EGM voltages obtained during SR and AF. In SR, vertical values were on average 66±119% larger than horizontal ( P =0.004). In AF, vertical values were on average 31±96% larger than horizontal ( P =0.07). Omnipole V max values were 99.9±125% larger than both horizontal (99.9±125%; P <0.001) and vertical (41±78%; P <0.0001) in SR and larger than both horizontal (76±109%; P <0.001) and vertical (52±70%; P value <0.0001) in AF. Vector field analysis of AF wavefronts demonstrates that omnipolar EGMs can account for collision and fractionation and record EGM voltages unaffected by these events. Conclusions: Omnipolar EGMs can extract maximal voltages from AF signals which are not influenced by directional factors, collision or fractionation, compared with contemporary bipolar techniques.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Haldar et al. (2017) studied this question.

synapsesocial.com/papers/6a0f8c5ab6f5ee04015fcb79https://doi.org/10.1161/circep.117.005018
Ask AI
Helpful
Bookmark
Share
View Full Paper