This is the authors' abstract. We don't add key points for this paper.
PURPOSE: To prospectively study the feasibility of femtosecond lenticule extraction (FLE), a new method of refractive correction. SETTING: Department of Ophthalmology, Philipps University of Marburg and Helios Clinic, Erfurt, Germany. METHODS: A flap and a lenticule of intrastromal corneal tissue were simultaneously cut with a VisuMax femtosecond laser system. Next, the lenticule was manually removed and the flap repositioned. The target refraction in all cases was -0.75 diopter (D). RESULTS: All 10 myopic eyes in the initial treatment group completed the final 6-month follow-up. The mean patient age was 39 years. The mean spherical equivalent (SE) was -4.73 +/- 1.48 (SD) preoperatively and -0.33 +/- 0.61 D 6 months postoperatively. Ninety percent of eyes were within +/-1.00 D and 40% were within +/-0.50 D of the intended correction. No eye lost 2 or more Snellen lines. Corneal topography showed large, prolate optical zones. Aberrometry showed no significant induction of higher-order aberrations. On a standardized questionnaire, all patients said they were very satisfied with the results. CONCLUSIONS: Preliminary results indicate that FLEx [corrected] is a promising new corneal refractive procedure to correct myopia.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Sekundo et al. (2008) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: