Why the study?
Standardizing cardiac valve structures and function to body surface area aids clinicians and surgeons in decision-making.
What are the reference values (Z-scores) for cardiac structural dimensions and function normalized to body surface area in healthy children in South East Nigeria compared to Western standards?
What are the reference values (Z-scores) for cardiac structural dimensions and function normalized to body surface area in healthy children in South East Nigeria compared to Western standards?
Cardiac structural and functional Z-scores in healthy Nigerian children are largely comparable to Western standard values, supporting the use of existing reference ranges with minor exceptions.
Answers are grounded in this paper and cite their sources.
Supports use of Western Z-score references locally; extends data to Nigerian children but leaves validation open.
BACKGROUND: Standardizing cardiac valve structures and function to body surface area will help the clinician and surgeons in decision-making. AIM: To evaluate the z-scores of the sizes of cardiac structures and function and to present them in Gaussian curves and reference values. MATERIALS AND METHODS: This was a cross-sectional study that involved 300 apparently healthy children. This study was performed among healthy children from birth to 18 years. Children with a normal echocardiogram, those with no chronic illness, no congenital heart defect, and no acquired heart defect were included in the study. RESULT: The majority fell within the normal limits, as shown in the Gaussian curves. For instance, 40 (13.3%) of atrioventricular (AV) valve diameters were +1 Z-score above the normal, and only 5 (1.7%) were +2 Z-score above the normal. About 9.3% (28/300) had below -2 Z-score below normal, while only 5% had -1 Z-score below normal. Similarly, the left ventricular function z-scores were also derived at -3 Z-scores to +3 Z-scores. The standard reference values were compared with the results obtained from our Z score values. There was no significant difference noted in the Z-scores. P values ranged from 0.07 to 0.84 for all the cardiac structures except for gender, where Z-scores of the mitral valve and left pulmonary artery varied significantly (P = 0.02). CONCLUSION: Reference values of cardiac structure and function were presented using Z scores, and we noted no significant difference when compared with the Western standard values except for the mitral valve and left pulmonary artery.
No takes yet. Share an insight, caveat, or question.
Chinawa et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: