PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 22, 2016Circulation Arrhythmia and Electrophysiology216 citationsOpen Access

Direct Proof of Endo-Epicardial Asynchrony of the Atrial Wall During Atrial Fibrillation in Humans

View Full Paper
NGNatasja de GrootLDLisette van der DoesAYAmeeta Yaksh

Key Result

Simultaneous high-resolution mapping during atrial fibrillation demonstrated asynchronous endo-epicardial activation (0.9-55.9%), with 65% of focal waves attributed to endo-epicardial excitation.

Study Design

Type

Observational (n=14)

Structured PICO

P
Population
14 patients undergoing intraoperative mapping (10 with AF: paroxysmal n=3, persistent n=4, longstanding persistent n=3; and 4 without a history of AF)
I
Intervention
Simultaneous high-resolution mapping of the right atrial endo- and epicardial wall using a clamp made of 2 rectangular 8×16 electrode arrays
O
Outcome
Incidence of asynchronous endo-epicardial activation times (≥15 ms) of opposite electrodessurrogate

This study provides the first direct evidence of asynchronous activation of the endo-epicardial wall during atrial fibrillation in humans, highlighting a potential mechanism for AF maintenance and therapy failure.

Main Result

Absolute Event Rate: 11% vs 13%

p-value: p=0.18

Abstract

BACKGROUND: The presence of focal fibrillation waves during atrial fibrillation (AF) can, besides ectopic activity, also be explained by asynchronous activation of the atrial endo- and epicardial layer and transmurally propagating fibrillation waves. To provide direct proof of endo-epicardial asynchrony, we performed simultaneous high-resolution mapping of the right atrial endo- and epicardial wall during AF in humans. METHOD AND RESULTS: Intraoperative mapping of the endo- and epicardial right atrial wall was performed during (induced) AF in 10 patients with AF (paroxysmal: n=3; persistent: n=4; and longstanding persistent: n=3) and 4 patients without a history of AF. A clamp made of 2 rectangular 8×16 electrode arrays (interelectrode distance 2 mm) was inserted into the incision in the right atrial appendage. Recordings of 10 seconds of AF were analyzed to determine the incidence of asynchronous endo-epicardial activation times (≥15 ms) of opposite electrodes. Asynchronous endo-epicardial activation ranged between 0.9 and 55.9% without preference for either side. Focal waves appeared equally frequent at endocardium and epicardium (11% versus 13%; ITALIC! P=0.18). Using strict criteria for breakthrough (presence of an opposite wave within 4 mm and ≤14 ms before the origin of the focal wave), the majority (65%) of all focal fibrillation waves could be attributed to endo-epicardial excitation. CONCLUSIONS: We provided the first evidence for asynchronous activation of the endo-epicardial wall during AF in humans. Endo-epicardial asynchrony may play a major role in the pathophysiology of AF and may offer an explanation why in some patients therapy fails.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Groot et al. (2016) conducted an observational in Atrial Fibrillation (n=14). Simultaneous high-resolution mapping of the right atrial endo- and epicardial wall was evaluated on Frequency of focal waves at endocardium versus epicardium (p=0.18). Simultaneous high-resolution mapping during atrial fibrillation demonstrated asynchronous endo-epicardial activation (0.9-55.9%), with 65% of focal waves attributed to endo-epicardial excitation.

synapsesocial.com/papers/6a0fc08192676d5461fd0ae0https://doi.org/10.1161/circep.115.003648
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Electropathological Substrate of Longstanding Persistent Atrial Fibrillation in Patients With Structural Heart Disease2010 · 357 citations
  2. 2CrossTalk opposing view: Rotors have not been demonstrated to be the drivers of atrial fibrillation2014 · 70 citations
  3. 3Time course and mechanisms of endo-epicardial electrical dissociation during atrial fibrillation in the goat2010 · 156 citations
  4. 4Incomplete Reentry and Epicardial Breakthrough Patterns During Atrial Fibrillation in the Sheep Heart1996 · 164 citations
  5. 5Driver Domains in Persistent Atrial Fibrillation2014 · 731 citations