Key result
Mechanical tricuspid valves link to better long-term survival versus biological prostheses in Ebstein's anomaly.
Why the study?
Evidence is lacking on whether a mechanical prosthesis is superior or inferior to a biological prosthesis in patients with Ebstein's anomaly.
Does mechanical tricuspid valve replacement improve long-term survival compared to biological tricuspid valve replacement in patients with Ebstein's anomaly?
Cohort (n=85)
Yes
Does mechanical tricuspid valve replacement improve long-term survival compared to biological tricuspid valve replacement in patients with Ebstein's anomaly?
In patients with Ebstein's anomaly undergoing tricuspid valve replacement, mechanical prostheses were associated with better long-term survival compared to biological prostheses.
Mechanical prostheses were associated with better survival after tricuspid replacement in Ebstein's anomaly; leaves open whether randomized data should alter prosthesis selection.
Background: Presently, it is still lack of evidence whether a mechanical prosthesis is superior or inferior to a biological prosthesis in patients with Ebstein’s anomaly. The aim of this study was to compare the long-term results of mechanical and biological prostheses of patients with Ebstein’s anomaly at two major cardiac surgical centers in central China. Methods: From January 1999 to June 2020, 85 patients with Ebstein’s anomaly (mean age: 42 ± 17 years, male to female ratio = 19: 66) underwent tricuspid valve replacement. 22 patients (26%) underwent mechanical valve implantation, and 63 (74%) were implanted with a bioprosthesis. Median follow-up duration was 145 months and mean follow-up duration was 146 ± 13 months. Operative results, long-term survival, and tricuspid valve-related events were compared. Results: Eight patients suffered from cardiac failure and died within 30 days after the surgery. Mechanical prostheses demonstrated a better survival outcome compared with biological prostheses before (p = 0.043) and after (p = 0.039) propensity score matching. Tricuspid valve-related events occurred in 20 patients. There was no statistical significance between mechanical and biological tricuspid valves before (p = 0.87) and after (p = 0.91) propensity score matching. Conclusions: Tricuspid valve replacement for patients with Ebstein’s anomaly is a high-risk operation and should be cautious, especially for patients with poor conditions. Although mechanical prostheses demonstrated a better survival outcome compared with biological prostheses in our study, the selection of prostheses should be individualized and consider each patient’s characteristics and needs.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2024) conducted a cohort in Ebstein's anomaly (n=85). Mechanical prosthetic replacement of the tricuspid valve vs. Biological prosthetic replacement was evaluated on Long-term survival (p=0.039). Mechanical prosthetic replacement of the tricuspid valve demonstrated better long-term survival compared with biological prostheses in patients with Ebstein's anomaly (p=0.039 after matching).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: