Key result
Mechanical tricuspid valve replacement shows comparable 10-year survival and valve-related events versus bioprosthetic valves.
Why the study?
Does mechanical tricuspid valve replacement improve survival or reduce valve-related events compared to bioprosthetic valve replacement in patients with tricuspid valvular disease?
Cohort (n=104)
Does mechanical tricuspid valve replacement improve survival or reduce valve-related events compared to bioprosthetic valve replacement in patients with tricuspid valvular disease?
Mechanical tricuspid valve replacement appears to have comparable long-term survival and valve-related event rates to bioprosthetic replacement after adjusting for baseline differences.
Answers are grounded in this paper and cite their sources.
Should not yet change tricuspid valve selection; extends observational data but leaves open need for randomized confirmation.
BACKGROUND: The purpose of this study was to evaluate the clinical outcomes and risk of tricuspid valve replacements and to compare bioprosthetic versus mechanical valves. METHODS: Between 1991 and 2009, 104 consecutive patients (71 women; mean age, 57 ± 10.8 years) with tricuspid valvular disease underwent mechanical TVR (mechanical group; n = 59) or bioprosthetic TVR (bioprosthesis group; n = 45). Follow-up was complete in 97.1% (n = 101) with a median duration of 49.9 months (range 0-230 months). RESULTS: Hospital mortality after mechanical TVR and bioprosthetic TVR was not different on adjusted analysis by propensity score. Ten-year actuarial survival after mechanical and bioprosthetic TVR was 83.9 ± 7.6% and 61.4 ± 9.1%, respectively (p = 0.004). However, there was also no significant difference in terms of adjusted analysis by propensity score (p = 0.084). No statistically significant difference was detected between mechanical and bioprosthetic valves in regard to event-free survival. CONCLUSIONS: Mechanical TVR is not inferior to bioprosthetic TVR in terms of occurrence of valve-related events, especially anticoagulation-related complications.
No takes yet. Share an insight, caveat, or question.
Cho et al. (2013) conducted a cohort in Tricuspid valvular disease (n=104). Mechanical tricuspid valve replacement vs. Bioprosthetic tricuspid valve replacement was evaluated on 10-year actuarial survival (p=0.004 (unadjusted); 0.084 (adjusted)). Mechanical tricuspid valve replacement was not inferior to bioprosthetic replacement for valve-related events and showed no significant difference in adjusted 10-year survival.
Synapse has enriched 10 related papers. Consider them for comparative context: