Key result
A technical error rating tool for laparoscopic surgery demonstrated high inter-rater reliability for errors and correlated with OSATS scores.
Why the study?
Does the proposed error rating tool allow objective and reliable assessment of operative performance in laparoscopic gastric bypass procedures?
Observational (n=25)
Does the proposed error rating tool allow objective and reliable assessment of operative performance in laparoscopic gastric bypass procedures?
The proposed error rating tool provides an objective and reliable assessment of operative performance in laparoscopic gastric bypass procedures.
Answers are grounded in this paper and cite their sources.
Promising for objective laparoscopic performance assessment; leaves open effects on training or outcomes.
BACKGROUND: Surgical error analysis is essential for investigating mechanisms of errors, events and adverse outcomes. Furthermore, it provides valuable information for formative feedback and quality control. The aim of the present study was to design and validate a technical error rating tool in laparoscopic surgery. METHODS: The framework consisted of nine task groups and four error modes. Unedited videos of laparoscopic Roux-en-Y gastric bypass procedures were rated and analysed. The Objective Structured Assessment of Technical Skill (OSATS) global rating scale was used to assess technical skills. The incidence of errors and of injuries (events) were the main outcome measures, and were used to calculate the reliability, and construct and concurrent validity of the instrument. RESULTS: Two observers analysed 25 procedures. Inter-rater reliability was high regarding total number of errors (intraclass correlation coefficient (ICC) 0·90) and events (ICC 0·85). The median (interquartile range) error rate was 35 (26-44) and the event rate 3 (2-3) per procedure. Error frequencies and OSATS scores correlated significantly in all operative steps (rs = -0·75 to -0·40, P = <0·001-0·046). Surgeons demonstrating high OSATS scores had lower median (i.q.r.) error rates than surgeons with low scores in three of four steps: measuring bowel (4 (2-7) versus 10 (9-11); P = 0·004), jejunojejunostomy formation (5 (2-6) versus 10 (9-11); P = 0·001) and pouch formation (4 (3-6) versus 9 (5-12); P = 0·004). CONCLUSION: The proposed error rating tool allows an objective and reliable assessment of operative performance in laparoscopic gastric bypass procedures.
No takes yet. Share an insight, caveat, or question.
Bonrath et al. (2013) conducted an observational in Laparoscopic surgery (Roux-en-Y gastric bypass) (n=25). Technical error rating tool vs. OSATS global rating scale was evaluated on Incidence of errors and of injuries (events). A technical error rating tool for laparoscopic surgery demonstrated high inter-rater reliability for errors and correlated with OSATS scores.
Synapse has enriched 10 related papers. Consider them for comparative context: