Why the study?
The suitability of high-power short-duration cavo-tricuspid isthmus ablation for electrophysiology trainees, along with the underlying mechanisms of its efficacy, was unknown.
Does high-power short-duration ablation improve first-pass bidirectional isthmus block compared to moderate-power long-duration ablation in patients undergoing cavo-tricuspid isthmus ablation performed by EP trainees?
Does high-power short-duration ablation improve first-pass bidirectional isthmus block compared to moderate-power long-duration ablation in patients undergoing cavo-tricuspid isthmus ablation performed by EP trainees?
High-power short-duration ablation for the cavo-tricuspid isthmus performed by EP trainees is safe, achieves higher first-pass block rates, and reduces procedure times compared to conventional moderate-power ablation.
Supports trainee use of TF-HPSD for CTI ablation; hypothesis-generating and requires randomized confirmation before practice change.
INTRODUCTION: The suitability of high-power short-duration (HPSD) cavo-tricuspid isthmus ablation (CTI-Abl) for electrophysiology (EP) trainees, as well as the underlying mechanisms of its efficacy, remain unknown. The aim of this study was to clarify the efficacy and safety of HPSD CTI-Abl performed by EP trainees and assess lesion characteristics between HPSD and moderate-power long duration (MPLD) ablations. METHODS: Study 1: CTI-Abl was performed by first- to fourth-year EP trainees in consecutive 113 patients (67 ± 11 years, 27.2% female). Study cohort was historically divided into three groups: MPLD (30-35 W for up to 30 s) using TactiCath (TC-MPLD, N = 38) and MPLD and HPSD (50 W for 12 s) using TactiFlex (TF-MPLD, N = 23; TF-HPSD, N = 52). Primary endpoint was first-pass bidirectional isthmus block (BIB). Study 2: lesion geometries created by each ablation strategy were compared using an ex-vivo model. RESULTS: Study 1: TF-HPSD ablation strategy demonstrated a higher success rate of first-pass BIB than MPLD protocol (TC-MPLD, 58%; TF-MPLD, 48%; TF-HPSD, 94%, p < 0.001), without any complications. TF-HPSD group was associated with shorter total procedure and RF application times, as well as fewer ablation points and gaps, compared to the MPLD groups. Study 2: TF-HPSD created greater lesion surface length, width, and area than MPLD strategies. CONCLUSION: HPSD CTI-Abl performed by EP trainees using TactiFlex SE catheter demonstrated a higher first-pass BIB rate, shorter total procedure and RF application times, and fewer ablation points and gaps compared to the conventional method, without increasing complication rates.
No takes yet. Share an insight, caveat, or question.
Iwakawa et al. (2024) studied this question.