Answers are grounded in this paper and cite their sources.
Study evaluate interface shear transfer capacity in GFRP-RC, suggesting a need for new design models.
Interface shear transfer (IST) is a critical mechanism governing composite action in reinforced concrete (RC) structures. While the IST behavior in steel-RC is well established, its application to glass fiber-reinforced polymer (GFRP)-RC remains uncertain due to the scatter of experimental data and the absence of a unified design model. This study assesses the accuracy of current IST design provisions and analytical models for GFRP-RC using a database of 107 push-off tests from the literature, including 56 specimens with an as-cast interface, 20 specimens with an intentionally roughened interface, 26 specimens with a monolithic interface, and five specimens with a smooth interface. Predictions of available models were compared with experimental peak loads. The results show that current provisions in design codes and standards either significantly underestimate or overestimate the IST capacity. The proposed analytical strain-based models in the literature improved predictions but exhibited inconsistencies across different interface conditions. Accordingly, a modified IST model is proposed based on regression analysis, incorporating a cohesion parameter as a function of the concrete strength with a GFRP strain limit of 0.003. The proposed model provides accurate, yet conservative, predictions across different interface conditions.
No takes yet. Share an insight, caveat, or question.
Ahmed et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: