Key result
Noninvasive echo-sPAP and creatinine model matches invasive assessment for discriminating elevated LVEDP.
Why the study?
Does noninvasive assessment using echo-sPAP and creatinine accurately reflect elevated directly measured LVEDP compared to invasive dPAP in patients undergoing routine cardiac catheterization?
Observational
No
Does noninvasive assessment using echo-sPAP and creatinine accurately reflect elevated directly measured LVEDP compared to invasive dPAP in patients undergoing routine cardiac catheterization?
Noninvasive echocardiographic and laboratory findings (echo-sPAP and creatinine) can modestly estimate elevated left ventricular filling pressure, functioning through an intermediate invasive pulmonary hemodynamic pattern.
Answers are grounded in this paper and cite their sources.
Echocardiographic markers warrant cautious LVEDP interpretation in practice; observational data leave open pulmonary hemodynamic mediation.
Background: Noninvasive echocardiographic markers are widely used to estimate left ventricular filling pressure, but their relationship with directly measured left ventricular end-diastolic pressure (LVEDP) is often modest and context-dependent. Whether routinely available noninvasive findings reflect elevated LVEDP through an intermediate invasive pulmonary hemodynamic phenotype remains insufficiently characterized. Objective: To evaluate the relationship of noninvasive echocardiographic and laboratory markers with directly measured LVEDP and to determine whether invasive pulmonary artery diastolic pressure (dPAP) functions as a hemodynamic bridge linking upstream noninvasive findings to elevated left ventricular filling pressure in a routine catheterization cohort. Methods: This retrospective single-center observational study included patients undergoing routine cardiac catheterization with available direct LVEDP measurement and invasive pulmonary artery pressure data. Elevated LVEDP was defined as LVEDP ≥ 15 mmHg, and elevated dPAP as dPAP ≥ 24 mmHg. Noninvasive, bridge, and invasive validation models were evaluated using logistic regression, receiver operating characteristic analysis, calibration assessment, and bootstrap internal validation. Results: A total of 75 patients had direct LVEDP data, 94 had invasive dPAP data, 83 had echocardiographic systolic pulmonary artery pressure (echo-sPAP), and 37 had pulmonary capillary wedge pressure (PCWP) measurements. Patients with elevated LVEDP had significantly higher creatinine (p = 0.026), dPAP (p = 0.043), and PCWP (p = 0.004). Echo-sPAP showed good discrimination for elevated dPAP, with an AUC of 0.791 (95% CI 0.695–0.888), supporting its role as an upstream noninvasive marker of invasive pulmonary hemodynamic burden. A noninvasive model combining echo-sPAP and creatinine showed modest discrimination for elevated LVEDP (AUC 0.664, 95% CI 0.522–0.806; Brier score 0.198), whereas an invasive validation model combining dPAP and creatinine showed better performance (AUC 0.734, 95% CI 0.617–0.850; Brier score 0.176). In bootstrap validation, the optimism-corrected AUCs were approximately 0.624 and 0.711, respectively. Although the invasive model performed numerically better, DeLong comparison did not show a statistically significant difference between the two models (p = 0.459). Conclusions: Routinely available noninvasive echocardiographic and laboratory findings appear to relate to directly measured left ventricular filling pressure through an intermediate invasive pulmonary hemodynamic pattern. Echo-sPAP showed its strongest signal at the level of elevated dPAP, whereas dPAP combined with creatinine provided the most informative model for elevated directly measured LVEDP. These findings support a hypothesis-generating hemodynamic framework linking noninvasive assessment to directly measured filling pressure and may help inform noninvasive hemodynamic triage and physiological risk enrichment in selected clinical settings.
No takes yet. Share an insight, caveat, or question.
Çelik et al. (2026) conducted an observational in Routine cardiac catheterization. Noninvasive model (echo-sPAP and creatinine) vs. Invasive validation model (dPAP and creatinine) was evaluated on Discrimination for elevated LVEDP (≥ 15 mmHg) (AUC 0.664 vs 0.734, 95% CI 0.522-0.806, p=0.459). A noninvasive model combining echo-sPAP and creatinine discriminated elevated LVEDP, which was not different from an invasive model.
Synapse has enriched 10 related papers. Consider them for comparative context: