Why the study?
Does the f99 repolarization index predict the occurrence of ventricular arrhythmias in patients with an implanted cardiac defibrillator?
Does the f99 repolarization index predict the occurrence of ventricular arrhythmias in patients with an implanted cardiac defibrillator?
The f99 repolarization index, particularly when maximized over three orthogonal leads, is a promising noninvasive predictor for ventricular arrhythmias in patients with ICDs.
Answers are grounded in this paper and cite their sources.
f99_MaxXYZ may identify higher arrhythmia risk in ICD patients; hypothesis-generating and requires prospective validation before clinical use.
BACKGROUND: Defects of cardiac repolarization, noninvasively identifiable by analyzing the electrocardiographic (ECG) ST segment and T wave, are among the major causes of sudden cardiac death. Still, no repolarization-based index has so far shown sufficient sensitivity and specificity to justify preventive treatments. Thus, the aim of this work was to evaluate the predictive power of our recently proposed f99 index for the occurrence of ventricular arrhythmias. METHODS: Our study populations included 170 patients with implanted cardiac defibrillator (ICD), 44 of which developed ventricular tachycardia and/or fibrillation during the 4-year follow-up (ICD_Cases) and 126 did not (ICD_Controls). The f99 index, defined as the frequency at which the repolarization normalized cumulative energy reaches 99%, was computed in each of the 15 (I to III, aVl, aVr, aVf, V1 -V6 , X, Y, Z) available ECG leads independently, and then maximized over the 6 precordial leads (f99_MaxV1 -V6 ), 12 standard leads (f99_Max12STD) and three orthogonal leads (f99_MaxXYZ) to avoid dispersion-related issues. Each index predictive power was quantified as the area under the receiving operating characteristic curve (AUC). RESULTS: Median f99_MaxV1 -V6 , f99_Max12STD and f99_MaxXYZ values were significantly higher in the ICD_Cases than in the ICD_Controls (48 Hz vs. 35 Hz, P<0.05; 51 Hz vs. 43 Hz, P<0.05; 45 Hz vs. 31 Hz, P<10(-3) ; respectively), indicating a more fragmented repolarization in the former group. The AUC values were 0.62, 0.63 and 0.68, respectively. CONCLUSIONS: The f99 represents a promising risk index for the occurrence of ventricular arrhythmias, especially when maximized over the three orthogonal leads.
No takes yet. Share an insight, caveat, or question.
Giuliani et al. (2015) studied this question.