Key result
Sinusoidal low-voltage shocks terminate re-entrant waves in short ventricular strands but fail in larger 2D tissues.
Why the study?
Strong electric shocks reliably terminate ventricular fibrillation but often cause post-injuries, motivating exploration of low-voltage shocks at certain frequencies for defibrillation.
Do sinusoidal low-voltage shocks result in successful defibrillation of human ventricular tissue models?
Do sinusoidal low-voltage shocks result in successful defibrillation of human ventricular tissue models?
Periodic low-voltage stimulation can defibrillate transmural re-entrant waves via standing waves in short ventricular tissue models, but fails and may be proarrhythmic on the ventricular surface.
Should not alter defibrillation practice; leaves open efficacy of standing-wave termination in human-scale ventricular models.
Ventricular fibrillation (VF) is one of the main causes of sudden cardiac death. Strong electric shocks remain the only reliable mechanism for successful termination of VF, but often lead to post-injuries. This study aims to explore whether low-voltage shocks at certain frequencies could result in successful defibrillation of human ventricular tissue. 1 D and 2D ventricular tissue models were based on the Ten Tusscher et al. myocyte model combined with an extended version of the bidomain model with an external bath, to which the electric shocks were delivered. Sinusoidal low-voltage (10–50 Hz, 20–40 V) shocks were applied at opposite sides of 1D tissue strands and 2D square tissues of variable sizes; in 2D models, VF was induced in form of a single re-entrant wave. In 1 D models, standing waves were observed at all frequencies in short ventricular strands (1–2 cm, comparable to the transmural distance in the human ventricles), but not in long strands (5–10 cm). Accordingly, in 2D tissue models of 5–10 cm², standing waves failed to form and terminate re-entry; otherwise, electrical waves originating from the shock application sites led to the generation of additional reentries. In summary, the formation of standing waves due to periodic low-voltage stimulation of human ventricular tissue can lead to defibrillation of transmural re-entrant waves, but not of rotors on the ventricular surface.
No takes yet. Share an insight, caveat, or question.
Georgiev et al. (2021) studied Ventricular fibrillation. Sinusoidal low-voltage shocks was evaluated on Formation of standing waves and successful termination of re-entry. Sinusoidal low-voltage shocks (10-50 Hz, 20-40 V) formed standing waves and terminated transmural re-entrant waves in short ventricular strands (1-2 cm), but failed in larger 2D tissue models.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: