Why the study?
Do research-grade and consumer-based wearables accurately measure heart rate and energy expenditure compared to criterion measures during dynamic exercise in persons with and without Type 1 Diabetes?
Do research-grade and consumer-based wearables accurately measure heart rate and energy expenditure compared to criterion measures during dynamic exercise in persons with and without Type 1 Diabetes?
Research-grade wearables demonstrate clinically acceptable accuracy (within ~10% error) for measuring heart rate and energy expenditure across dynamic exercise intensities.
Answers are grounded in this paper and cite their sources.
Provides preliminary support for wearable monitoring during exercise in T1D; leaves open validation in larger trials before clinical adoption.
Background: The increasing popularity of wearable technology necessitates the evaluation of their accuracy to differentiate physical activity (PA) intensities. These devices may play an integral role in customizing PA interventions for primary prevention and secondary management of chronic diseases. For example, in persons with type 1 diabetes (T1D), PA greatly affects glucose concentrations depending on the intensity, mode (ie, aerobic, anaerobic, mixed), and duration. This variability in glucose responses underscores the importance of implementing dependable wearable technology in emerging avenues such as artificial pancreas systems. Methods: Participants completed three 40-minute, dynamic non-steady-state exercise sessions, while outfitted with multiple research (Fitmate, Metria, Bioharness) and consumer (Garmin, Fitbit) grade wearables. The data were extracted according to the devices’ maximum sensitivity (eg, breath by breath, beat to beat, or minute time stamps) and averaged into minute-by-minute data. The variables of interest, heart rate (HR), breathing frequency, and energy expenditure (EE), were compared to validated criterion measures. Results: Compared to deriving EE by laboratory indirect calorimetry standard, the Metria activity patch overestimates EE during light-to-moderate PA intensities (L-MI) and moderate-to-vigorous PA intensities (M-VI) (mean ± SD) (0.28 ± 1.62 kilocalories· minute -1 , P < .001, 0.64 ± 1.65 kilocalories· minute -1 , P < .001, respectively). The Metria underestimates EE during vigorous-to-maximal PA intensity (V-MI) (–1.78 ± 2.77 kilocalories · minute -1 , P < .001). Similarly, compared to Polar HR monitor, the Bioharness underestimates HR at L-MI (–1 ± 8 bpm, P < .001) and M-VI (5 ± 11 bpm, P < .001), respectively. A significant difference in EE was observed for the Garmin device, compared to the Fitmate ( P < .001) during continuous L-MI activity. Conclusions: Overall, our study demonstrates that current research-grade wearable technologies operate within a ~10% error for both HR and EE during a wide range of dynamic exercise intensities. This level of accuracy for emerging research-grade instruments is considered both clinically and practically acceptable for research-based or consumer use. In conclusion, research-grade wearable technology that uses EE kilocalories · minute -1 and HR reliably differentiates PA intensities.
No takes yet. Share an insight, caveat, or question.
Yavelberg et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: