Key result
Level 2 automated cardiac MRI processing outpaces manual assessment and achieves ~98% LVEDV accuracy.
Why the study?
Automating cardiac function assessment on CMR short-axis cines is faster and more reproducible than manual contour-tracing, but accurately tracing basal contours remains challenging.
Does automated post-processing software improve speed and maintain accuracy compared to manual assessment in cardiac magnetic resonance function post-processing in healthy subjects?
Observational (n=65)
Does automated post-processing software improve speed and maintain accuracy compared to manual assessment in cardiac magnetic resonance function post-processing in healthy subjects?
Level 2 automation (automated tracing with standardized manual adjustment) balances speed and accuracy for cardiac magnetic resonance function post-processing compared to fully manual or fully automated methods.
Answers are grounded in this paper and cite their sources.
May support Level 2 automation to speed CMR analysis in healthy subjects; leaves open validation in patients and outcome impact.
Automating cardiac function assessment on cardiac magnetic resonance short-axis cines is faster and more reproducible than manual contour-tracing; however, accurately tracing basal contours remains challenging. Three automated post-processing software packages (Level 1) were compared to manual assessment. Subsequently, automated basal tracings were manually adjusted using a standardized protocol combined with software package-specific relative-to-manual standard error correction (Level 2). All post-processing was performed in 65 healthy subjects. Manual contour-tracing was performed separately from Level 1 and 2 automated analysis. Automated measurements were considered accurate when the difference was equal or less than the maximum manual inter-observer disagreement percentage. Level 1 (2.1 ± 1.0 min) and Level 2 automated (5.2 ± 1.3 min) were faster and more reproducible than manual (21.1 ± 2.9 min) post-processing, the maximum inter-observer disagreement was 6%. Compared to manual, Level 1 automation had wide limits of agreement. The most reliable software package obtained more accurate measurements in Level 2 compared to Level 1 automation: left ventricular end-diastolic volume, 98% and 53%; ejection fraction, 98% and 60%; mass, 70% and 3%; right ventricular end-diastolic volume, 98% and 28%; ejection fraction, 80% and 40%, respectively. Level 1 automated cardiac function post-processing is fast and highly reproducible with varying accuracy. Level 2 automation balances speed and accuracy.
No takes yet. Share an insight, caveat, or question.
Snel et al. (2021) conducted an observational in Healthy subjects (n=65). Automated post-processing software (Level 1 and Level 2) vs. Manual contour-tracing was evaluated on Accuracy of measurements and processing time. Level 2 automated cardiac MRI post-processing was faster than manual assessment and achieved 98% accuracy for left ventricular end-diastolic volume compared to 53% for Level 1.