Answers are grounded in this paper and cite their sources.
PURPOSE: The aim of this study was to investigate if 3.0-T diffusion-weighted magnetic resonance imaging (MRI) can be used for early detection of acute occlusive and nonocclusive mesenteric ischemia. MATERIALS AND METHODS: In this study, approved by the official committee on animal affairs, proximal (occlusive) mesenteric ischemia and peripheral (nonocclusive) mesenteric ischemia were induced in 8 and 2, respectively, female domestic pigs. Proximal mesenteric ischemia was induced by intra-arterial injection of n-butyl-cyanoacrylate in the superior mesenteric artery or 1 of its main branches; peripheral mesenteric ischemia was induced by intra-arterial injection of microparticles. Before embolization and at 30-, 60-, and 90-minute intervals after embolization, diffusion-weighted imaging was performed, and apparent diffusion coefficient (ADC) maps were calculated on a clinical 3.0-T system. Immediately after the last MRI session, animals were killed to provide a pathological correlation for mesenteric ischemia. RESULTS: Ischemic bowel parts appeared hyperintense on diffusion-weighted images and hypointense on the corresponding ADC maps. Mean diffusion-weighted imaging signal intensity increased and ADC decreased significantly within 30 minutes after embolization (P < 0.001) and remained unchanged until 90 minutes after injury, independent of the embolization method. CONCLUSIONS: 3.0-Tesla diffusion-weighted MRI may help detect acute mesenteric ischemia as early as 30 minutes after vessel occlusion.
No takes yet. Share an insight, caveat, or question.
Bruhn et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: