Key result
DenseNet network identifies key intracardiac electrogram feature points with up to 0.42 ms average error.
Why the study?
Intracardiac electrogram feature points help assess excitation patterns and low-voltage areas to guide ablation targets in atrial fibrillation, making automated feature point extraction valuable.
A DenseNet deep learning model can accurately identify key feature points in intracardiac electrogram signals with sub-millisecond error, potentially assisting in locating ablation targets for atrial fibrillation.
Answers are grounded in this paper and cite their sources.
May aid automated electrogram annotation during AF ablation; leaves open impact on procedural outcomes.
During radiofrequency ablation procedures for atrial fibrillation patients, physicians can assist in locating ablation targets by analyzing the conduction pathways and low-voltage areas of the intracardiac electrogram signals. The feature points of intracardiac electrogram signals serve as criteria for assessing excitation patterns and low-voltage areas. Therefore, extracting feature points from intracardiac signals is of significant value. To identify key points in intracardiac electrogram signals through deep learning, this experiment collected intracardiac electrogram signals from 21 clinical patients, which were then filtered using wavelet transformation. Subsequently, each excitation was treated as a signal group, indicating the key feature points within. Finally, a total of 36,183 groups of intracardiac electrogram signals annotated with key points were obtained. The dataset consisted of data from 17 patients allocated for training, data from 2 patients reserved for testing, and data from the remaining 2 patients designated for validation purposes. Training was conducted using a DenseNet network incorporating both convolutional attention and feature pyramid modules. The final network successfully identifies the feature points of intracardiac electrogram signals. It outputs six feature points, including the starting point, first rising point, first falling point, peak point, valley point, and termination point, with average absolute errors of only 0.34, 0.27, 0.31, 0.01, 0.27, and 0.42 ms, respectively. The final detection results are highly satisfactory, indicating the potential utility of the findings in assisting the analysis of intracardiac electrogram signals. The research outcomes presented in this paper lay a foundation for the analysis of intracardiac electrogram signals.
No takes yet. Share an insight, caveat, or question.
Yihang et al. (2024) studied Atrial fibrillation (n=21). DenseNet network with convolutional attention and feature pyramid modules was evaluated on Average absolute errors of six feature points (starting, first rising, first falling, peak, valley, and termination points). A DenseNet network successfully identified six key feature points of intracardiac electrogram signals with average absolute errors ranging from 0.01 to 0.42 ms.
Synapse has enriched 10 related papers. Consider them for comparative context: