PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
July 1, 1997Heart170 citationsOpen Access

Non-invasive measurement of endothelial function: effect on brachial artery dilatation of graded endothelial dependent and independent stimuli.

View Full Paper
PLPaul LeesonSTSara ThorneADAnn E. Donald

Structured PICO

Do varying durations of cuff occlusion and doses of sublingual ISDN produce consistent and reproducible measures of endothelial function in healthy adults?

P
Population
6 healthy young adults (3 males, 3 females), mean age 31 years (range 25 to 43), with no known risk factors for cardiovascular disease.
I
Intervention
Forearm cuff occlusion for varying durations (30 seconds, 1.5, 2.5, 3.5, 4.5, and 8 minutes) and sublingual isosorbide dinitrate (ISDN) at varying doses (10, 20, 50, 100, 200, and 400 micrograms), administered in random order.
C
Comparator
Different durations of cuff occlusion and different doses of ISDN (dose-response and duration-response evaluation).
O
Outcome
Flow mediated, endothelial dependent dilatation compared to duration of cuff occlusion, peak reactive hyperaemia, and duration of increased flow; Nitrate induced, endothelial independent dilatation compared to dose of ISDN and change in flow.surrogate

A 4.5-minute cuff occlusion and 200 micrograms of sublingual ISDN are optimal for consistently measuring endothelial-dependent and independent brachial artery dilatation.

Abstract

OBJECTIVE: To examine the relation between endothelial dependent and endothelial independent stimuli of varying intensity and measures of vascular function in the brachial artery of young healthy adults, to determine whether these responses are consistent and can be used to assess endothelial function. DESIGN AND SETTING: High resolution ultrasound was used to measure brachial artery diameter at rest, after reactive hyperaemia induced by forearm cuff occlusion, and after sublingual isosorbide dinitrate (ISDN). Each subject was assigned to a random order of six cuff occlusion times (30 seconds, 1.5, 2.5, 3.5, 4.5, and 8 minutes) and six doses of ISDN (10, 20, 50, 100, 200, and 400 micrograms). SUBJECTS: Three males and three females mean age 31 years (range 25 to 43) with no known risk factors for cardiovascular disease. MAIN OUTCOME MEASURES: Flow mediated, endothelial dependent dilatation was compared to duration of cuff occlusion, peak reactive hyperaemia, and duration of increased flow. Nitrate induced, endothelial independent dilatation was compared to dose of ISDN and change in flow. RESULTS: Vessel dilatation and duration of peak flow change increased with longer duration of cuff occlusion. After 4.5 minutes of occlusion, flow mediated dilatation was mean (SD) 96 (6)% of maximal response and did not increase significantly with longer occlusion times. No significant dilatation occurred after 10 or 20 micrograms of ISDN in any subject. With increasing doses up to 200 micrograms there was an increase in dilatation. Endothelial independent dilatation did not increase significantly with doses of ISDN above 200 micrograms. CONCLUSIONS: Measures of arterial function vary with duration of blood flow occlusion and ISDN dose. Maximum arterial response was reached in all subjects after 4.5 minutes of blood flow occlusion or 200 micrograms of ISDN. Therefore, these variables produce consistent reproducible measures of endothelial function.