Key result
Epicardial electrogram amplitude is inversely related to epicardial fat thickness, with 31% of recordings over thick fat measuring <0.5 mV, potentially mimicking scar tissue.
Why the study?
Does epicardial fat thickness influence epicardial bipolar electrogram amplitude in patients undergoing open-heart surgery?
Observational (n=10)
Does epicardial fat thickness influence epicardial bipolar electrogram amplitude in patients undergoing open-heart surgery?
Answers are grounded in this paper and cite their sources.
Epicardial fat thickness significantly reduces epicardial bipolar electrogram amplitude, indicating that a standard 0.5 mV cut-off for defining scar may falsely identify normal myocardium with thick overlying fat as scar tissue.
AIMS: Reference values exist for endocardial but not for epicardial (EPI) substrate mapping in cases of cardiomyopathy-associated ventricular tachycardia. We sought to establish such values for EPI electrogram voltage, including areas with overlying fat. METHODS AND RESULTS: Ten patients (six males) undergoing cardiac surgery were studied. After opening the pericardium, the distal bipole of an electrophysiology catheter was placed tangential to the EPI surface to obtain an electrogram recording. The bipole was tangentially rotated 90 degrees and the higher of the two amplitudes (mV) was taken as the local amplitude. Recordings were taken from normal left and right ventricular myocardium (n = 26 data points each), over thick (> or = 0.5 cm) fat at both ventricular bases (n = 16) and thin (<0.5 cm) fat at the mid-ventricular level (n = 32). A total of 100 recordings (mean 10/patient) were analysed. Four patients underwent valvular surgery, three bypass surgery, and three combined procedures. Mean age was 61.7 +/- 10.4 years and mean left ventricular ejection fraction was 46 +/- 12%. Electrogram amplitude was inversely related to EPI fat thickness. Over thick fat, 31% of recordings were <0.5 mV. CONCLUSION: Human EPI electrogram amplitude varies by ventricular chamber and significantly by EPI fat thickness. A cut-off of 0.5 mV to define 'scar' will include normal areas with thick overlying fat. EPI substrate maps should include data on EPI fat thickness for higher specificity.
No takes yet. Share an insight, caveat, or question.
Saba et al. (2009) conducted an observational in Patients undergoing open-heart surgery (n=10). Epicardial bipolar electrogram mapping was evaluated on Epicardial electrogram amplitude (mV) in relation to fat thickness. Epicardial electrogram amplitude is inversely related to epicardial fat thickness, with 31% of recordings over thick fat measuring <0.5 mV, potentially mimicking scar tissue.
Synapse has enriched 10 related papers. Consider them for comparative context: