A novel computational method using biplane cineangiography allows for smooth, unconstrained estimation of epicardial strain from coronary artery motion.
Answers are grounded in this paper and cite their sources.
Allows smooth epicardial strain mapping from routine angiography without isotropy assumptions; leaves open clinical utility pending validation.
A quantitative method is described for estimating epicardial deformation from the motion of the superficial arteries. A structural model of the time-varying surface is constructed using tensor product basis functions which are bicubic Hermite in the spatial domain and sinusoidal in the temporal domain. The loci of the superficial coronary arteries are reconstructed interactively at diastasis and the bifurcations are tracked semiautomatically throughout a cardiac cycle. An initial surface is fitted to the vessels at diastasis and is subsequently deformed under the influence of the bifurcations. The Lagrange-Green strain tensor is used to obtain a complete description of surface strain over the entire region spanned by the model. The calculated deformation field varies smoothly over space and time and is not constrained by assumptions of isotropy or piecewise homogeneity. Results are presented for a single cycle of a human heart.
No takes yet. Share an insight, caveat, or question.
Young et al. (1992) studied this question.