Key result
High-power short-duration ablation increases odds of 1-year atrial arrhythmia freedom ~93% versus conventional ablation.
Why the study?
The authors aimed to further evaluate the comparative effectiveness and safety of high-power short-duration versus conventional radiofrequency ablation in patients with atrial fibrillation.
Does high-power short-duration radiofrequency ablation improve effectiveness and safety compared to conventional radiofrequency ablation in patients with atrial fibrillation?
Meta-Analysis (n=4,934)
Does high-power short-duration radiofrequency ablation improve effectiveness and safety compared to conventional radiofrequency ablation in patients with atrial fibrillation?
Effect estimate: OR 1.93 (95% CI 1.27-2.91)
p-value: p=0.002
High-power short-duration radiofrequency ablation for atrial fibrillation significantly reduces procedure time and improves 1-year freedom from atrial arrhythmia compared to conventional ablation, without increasing complications.
Supports HPSD (40-50W) ablation for AF; extends RCT evidence for higher 1-year success and shorter procedures.
Aims: We aimed to further evaluate the effectiveness and safety between high-power short-duration (HPSD) radiofrequency ablation (RFA) and conventional RFA in patients with atrial fibrillation (AF). Methods: Studies comparing HPSD and conventional applications from inception through December 2021 were searched on Pubmed, Medline, Cochrane and Clinicaltrials.gov. Results: The meta-analysis included seventeen studies with a total of 4934 patients. HPSD group decreased procedure duration [mean difference (MD) -38.28 min, 95% confidence interval (CI) -47.08 to -29.49, P<0.001], RF duration (MD -20.51 min, 95% CI -25.96 to -15.06, P<0.001) and fluoroscopy duration (MD -5.19 min, 95% CI -8.02 to -2.37, P<0.001), while improving the rates of first-pass isolation [Odds Ratio (OR) 8.92, 95% CI 2.40-33.09, P=0.009]. Compared with conventional group, freedom from atrial arrhythmia at 1-year-followup was higher in the HPSD group with a power setting of 40-50W (OR 1.93, 95% CI 1.27-2.91, P=0.002), nevertheless, two groups had similar effectiveness with a power setting of 50W in the HPSD RFA (OR 1.10, 95% CI 0.83-1.46, P=0.52). Acute pulmonary vein reconnection (P<0.001) was significantly lower in the HPSD group. There was no difference in complications between the two groups (P=0.71). Conclusion: HPSD RFA was associated with shorter procedure duration, higher freedom from atrial arrhythmia and comparable safety when compared with conventional RFA.
No takes yet. Share an insight, caveat, or question.
Jin et al. (2022) conducted a meta-analysis in Atrial fibrillation (AF) (n=4,934). High-power short-duration (HPSD) radiofrequency ablation vs. Conventional radiofrequency ablation was evaluated on Freedom from atrial arrhythmia at 1-year follow-up (40-50W power setting) (OR 1.93, 95% CI 1.27-2.91, p=0.002). High-power short-duration radiofrequency ablation (40-50W) increased freedom from atrial arrhythmia at 1 year compared to conventional ablation (OR 1.93; 95% CI 1.27-2.91; P=0.002).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: