Key result
Duty-cycled multi-electrode RF ablation yielded comparable 3-year single-procedure success without antiarrhythmic drugs compared to conventional point-by-point RF ablation (65% vs 55%, P=NS).
Why the study?
Does duty-cycled multi-electrode RF ablation improve freedom from arrhythmia compared to conventional irrigated point-by-point RF ablation in patients with symptomatic AF?
Cohort (n=161)
Does duty-cycled multi-electrode RF ablation improve freedom from arrhythmia compared to conventional irrigated point-by-point RF ablation in patients with symptomatic AF?
Answers are grounded in this paper and cite their sources.
Duty-cycled multi-electrode RF ablation provides comparable 3-year freedom from arrhythmia compared to conventional irrigated point-by-point RF ablation for patients with symptomatic AF.
AIMS: Pulmonary vein isolation (PVI) is an accepted treatment to relieve symptoms in patients with atrial fibrillation (AF). We studied 3 year outcome after PVI guided by duty-cycled multi-electrode radiofrequency (RF) ablation (pulmonary vein ablation catheter, PVAC) and provided comparative data to outcome after conventional PVI (CPVI) using mapping with irrigated, point-per-point RF ablation. METHODS AND RESULTS: One hundred and sixty-one consecutive patients with symptomatic paroxysmal or persistent AF and minimal heart disease underwent PVI (PVAC, n = 79 vs. CPVI, n = 82). Follow-up (with symptom-guided rhythm monitoring) was truncated at 3 years in all patients. Success was defined as freedom of documented arrhythmia after a single procedure and without antiarrhythmic drug treatment (ADT). Baseline characteristics did not differ between both groups. At 3 years follow-up, single-procedure success without ADT was comparable between PVAC and CPVI (65% vs. 55%, P = NS). The majority of recurrences occurred during the first year (PVAC 79% vs. CPVI 70%, P = NS). The annual rate of very late recurrence (i.e. beyond 1 year) was similar in both groups (10.5% vs. 15%, P = NS). CONCLUSION: At 3 years follow-up, outcome after PVAC-guided PVI is comparable to conventional isolation by irrigated point-by-point RF ablation. In both strategies, the majority of recurrences occurred in the first year of ablation.
No takes yet. Share an insight, caveat, or question.
Greef et al. (2014) conducted a cohort in Symptomatic paroxysmal or persistent atrial fibrillation (n=161). Duty-cycled multi-electrode radiofrequency ablation (PVAC) vs. Conventional irrigated point-by-point radiofrequency ablation (CPVI) was evaluated on Single-procedure success (freedom of documented arrhythmia) without antiarrhythmic drug treatment (p=NS). Duty-cycled multi-electrode RF ablation yielded comparable 3-year single-procedure success without antiarrhythmic drugs compared to conventional point-by-point RF ablation (65% vs 55%, P=NS).
Synapse has enriched 10 related papers. Consider them for comparative context: