Key result
Right parasternal approach yields a higher AT/ET ratio of ~0.34 versus apical approaches.
Why the study?
Although ejection time, acceleration time, and their ratio (AT/ET) are known indexes of aortic stenosis severity, the acoustic window dependency of AT/ET is not well studied.
Does the acoustic window approach affect the ratio of acceleration time to ejection time (AT/ET) in patients with aortic stenosis?
Observational (n=81)
Does the acoustic window approach affect the ratio of acceleration time to ejection time (AT/ET) in patients with aortic stenosis?
Answers are grounded in this paper and cite their sources.
The ratio of acceleration time to ejection time (AT/ET) for assessing aortic stenosis severity varies by acoustic window, with apical 3-chamber or 5-chamber approaches being preferable to the right parasternal approach.
Background: Echocardiographic transaortic jet velocity (Vmax), mean pressure gradient (mPG), and aortic valve area (AVA) are routinely measured for severity of aortic stenosis (AS). Additionally, prolonged ejection time (ET), acceleration time (AT), and its ratio AT/ET are also known as indexes of AS severity. However, acoustic window dependency of AT/ET is not well studied. Methods: Eighty-one patients with AS assessed by transaortic jet tracing of all of three approaches (apical 3-chamber (3C), apical 5-chamber (5C), and right parasternal (R)) were included in this study. ET, AT, and AT/ET were measured on continuous Doppler recordings obtained by 3C, 5C, and R approaches. Also, ET and AT were corrected by dividing by (R-R interval)1/2, and they were named as cET and cAT. Results: No differences were observed in cET among 3 approaches. However, cAT was significantly longer in R (115+23 msec: p<0.05) compared to that of 3C (105+21 msec) or 5C (105+20 msec). AT/ET was significantly greater in R (0.340+0.058, p<0.05) compared to that of 3C (0.317+0.053) or 5C (0.316+0.055). AT/ET-peak V relation of R approach positioned significantly upward (ANCOVA, p<0.05) comparing to that of 3C or 5C. Also, AT/ET-AVAi relation of R approach positioned upward (ANCOVA, p<0.05) comparing to that of 3C or 5C. Conclusions: AT/ET by R approach was greater than that by 3C or 5C approach. Although multiple acoustic window’s approaches including R is recommended to obtain the maximal Vmax or mPG, AT/ET is better in 3C or 5C approach than R when AT/ET is used for AS severity.
No takes yet. Share an insight, caveat, or question.
Sasaki et al. (2021) conducted an observational in Aortic Stenosis (n=81). Right parasternal (R) approach vs. Apical 3-chamber (3C) and 5-chamber (5C) approaches was evaluated on AT/ET ratio (p=<0.05). The AT/ET ratio measured by the right parasternal approach was greater than that measured by the apical 3-chamber or 5-chamber approaches.
Synapse has enriched 10 related papers. Consider them for comparative context: