Key result
Tissue Doppler echocardiography demonstrated a moderate positive correlation with electrophysiological study for measuring intra-left atrial conduction time.
Why the study?
Does tissue Doppler echocardiography correlate with invasive electrophysiological study for the measurement of atrial conduction times in patients with palpitations or supraventricular tachycardia?
Cross-Sectional (n=101)
Single-blind
No
Does tissue Doppler echocardiography correlate with invasive electrophysiological study for the measurement of atrial conduction times in patients with palpitations or supraventricular tachycardia?
Tissue Doppler echocardiography demonstrates a moderate correlation with invasive electrophysiological studies for measuring intra-left atrial conduction time, suggesting it is a useful noninvasive tool for evaluating atrial substrate.
Answers are grounded in this paper and cite their sources.
Supports noninvasive atrial conduction assessment; cross-sectional correlation leaves prospective validation open.
BACKGROUND: The main purpose of this study is to determine the correlation of inter- and intraatrial conduction times between the electrophysiological and tissue Doppler echocardiographic measurements, and to evaluate the appropriateness of tissue Doppler echocardiography for this measurement. METHODS: One-hundred and one patients were included in the study who underwent electrophysiological study for clinical arrhythmias. Inter- and intraatrial conduction times were measured from intracardiac electrograms. Atrial conduction times were also measured by tissue Doppler echocardiography by evaluating atrial electromechanical delay between lateral mitral annulus, septal mitral annulus, and right ventricular tricuspid annulus. The correlation between electrophysiological and echocardiographic atrial conduction times were analyzed. RESULTS: We found a weak correlation between the measurements of interatrial conduction times with the electrophysiological and tissue Doppler techniques (r = 0.308; p = 0.002). The correlation for intraleft atrial conduction times was moderate (r = 0.652; p 〈 0.001). There was no correlation between the measurements of intra-right atrial conduction times. CONCLUSIONS: We concluded that tissue Doppler echocardiography can be used for the measurement of interatrial and intra-left atrial conduction times. Tissue Doppler echocardiography can be a suitable technique to evaluate atrial substrate.
No takes yet. Share an insight, caveat, or question.
Deniz et al. (2012) conducted a cross-sectional in Clinical arrhythmias (palpitations or supraventricular tachycardia) (n=101). Tissue Doppler echocardiography vs. Electrophysiological study was evaluated on Correlation of intra-left atrial conduction time (ILCT) between tissue Doppler echocardiography and electrophysiological study (r = 0.652, p=<0.001). Tissue Doppler echocardiography demonstrated a moderate positive correlation with electrophysiological study for measuring intra-left atrial conduction time.
Synapse has enriched 10 related papers. Consider them for comparative context: