Key result
TDI correlates significantly with EPS for measuring total atrial conduction time in healthy adults.
Why the study?
Does tissue Doppler imaging (TDI) accurately measure total atrial conduction time compared to an electrophysiological study (EPS) in healthy adults?
Cross-Sectional (n=80)
Blinded evaluators
No
Does tissue Doppler imaging (TDI) accurately measure total atrial conduction time compared to an electrophysiological study (EPS) in healthy adults?
Tissue Doppler imaging provides a valid and non-invasive alternative to electrophysiological studies for measuring total atrial conduction time in healthy individuals.
Answers are grounded in this paper and cite their sources.
TDI may offer a non-invasive TACT surrogate in healthy adults; leaves open validation in disease and outcome studies.
BACKGROUND: We sought to validate total atrial conduction time (TACT) measurement via tissue Doppler imaging (TDI) by comparing the electrophysiological study (EPS) measurements of healthy subjects, according to age and sex. METHODS: Eighty patients with normal EPS results were included. TACT was measured by EPS and TDI. For validation, the results of TDI were compared with those of EPS. TACT was assessed by measuring the time interval between the beginning of the P-wave on the surface ECG, and the peak A-wave on TDI from the left atrial lateral wall, just over the mitral annulus. Electrophysiological TACT was defined as the time from the high right atrial electrogram to the distal coronary sinus atrial electrogram around the left lateral portion of the mitral ring. RESULTS: EPS and TDI measurements of the TACT were significantly and positively correlated among men and women in 20-30 years (p=0.008, r=0.412; p>0.001, r=0.706, respectively), and those in the 30-40 years group (p=0.001, r=0.649; p=0.001, r=0.696). In contrast, EPS and TDI measurements of TACT were not significantly different among men and women in the 20-30 years and those in the 30-40 years group (p>0.05, for both). On univariate regression analyses, TACT was independently associated with age (β=0.342, =0.001). CONCLUSIONS: When assessed according to the age and sex of healthy participants, TDI and EPS measurements during TACT assessments were similar and correlated with each other. The measurement of TACT via TDI may be used accurately and confidently than the measurement via EPS in healthy individuals.
No takes yet. Share an insight, caveat, or question.
Erdem et al. (2015) conducted a cross-sectional in Healthy adults with normal EPS results (n=80). Tissue Doppler imaging (TDI) vs. Electrophysiological study (EPS) was evaluated on Correlation of total atrial conduction time (TACT) between TDI and EPS (p=0.041). Tissue Doppler imaging and electrophysiological study measurements of total atrial conduction time were similar and significantly correlated across age and sex groups in healthy adults.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: