Compares PTFE tape and coating effects on removal torque and preload in titanium screws, indicating treatment implications.
OBJECTIVE: This study aimed to compare the effect of PTFE tape wrapping and PTFE-coated titanium alloy screws on the removal torque after cyclic loading and on preload values under repetitive tightening. METHODS: A total of 60 titanium abutment screws were allocated to three surface-treatment groups (n = 20 each): untreated (Control), PTFE tape-wrapped (Wrap), and PTFE-coated (Coat). Within each group, 10 specimens underwent cyclic loading, whereas 10 were assigned to preload evaluation. Cyclic loading followed ISO 14801:2016. Screws were tightened to 30 N·cm, retightened after 10 min, and subjected to 300 000 cycles at 200 N using a fatigue testing machine (DYNA-MESS Prüfsysteme GmbH, Aachen, Germany). Removal torque was measured with a digital torque gauge (BTGE50CN, Tohnichi, Japan). For preload assessment, each specimen completed 10 tightening-loosening cycles at the same torque during which tensile force was recorded using a customized device. One representative screw per group was analyzed by SEM and micro-CT before and after loading to evaluate surface and structural changes. RESULTS: After cyclic loading, the removal torque did not differ significantly between the Control group (17.58 ± 1.85 N·cm) and the Wrap group (17.50 ± 1.77 N·cm), whereas the Coat group demonstrated significantly lower removal torque (14.71 ± 2.35 N·cm; p < 0.05). In the preload test, preload progressively decreased in the Control (-3.13 N per cycle) and Coat groups (-0.51 N per cycle), while the Wrap group showed a consistent increase with repeated tightening (+8.22 N per cycle). SEM revealed surface wear and partial loss of PTFE material after loading, particularly in the coated specimens. Micro-CT analysis showed no detectable differences in internal adaptation among groups before or after cyclic loading. CONCLUSIONS: PTFE tape wrapping increased preload during repeated tightening but did not improve removal torque after cyclic loading compared with those of untreated screws. Although PTFE-coated screws produced the highest initial preload, they were associated with reduced removal torque after loading. SEM analysis confirmed coating deterioration, whereas internal fit remained comparable across groups.
No takes yet. Share an insight, caveat, or question.
Kongkhuntian et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: