Key result
Ultra high density-activation sequence mapping guided ablation directly terminated or eliminated atypical atrial flutter in 90.3% of arrhythmias.
Why the study?
Does ultra high density-activation sequence mapping (UHD-ASM) guided ablation improve termination of atypical atrial flutters in patients with AAF?
Observational (n=23)
No
Does ultra high density-activation sequence mapping (UHD-ASM) guided ablation improve termination of atypical atrial flutters in patients with AAF?
UHD-ASM allows for rapid identification of the entire atypical atrial flutter circuit and area of slow conduction, enabling successful ablation without entrainment mapping in over 90% of cases.
Answers are grounded in this paper and cite their sources.
May support UHD-ASM guided AAF ablation without entrainment; hypothesis-generating case report requiring prospective trials.
PURPOSE: The purpose of this study was to evaluate ultra high density-activation sequence mapping (UHD-ASM) for ablating atypical atrial flutters. METHODS: For 23 patients with 31 atypical atrial flutters (AAF), we created UHD-ASM. RESULTS: Demographics age = 65.3 ± 8.5 years, male = 78%, left atrial size = 4.66 ± 0.64 cm, redo ablation 20/23(87%). AAF were left atrial in 30 (97%). For each AAF, 1273 ± 697 points were used for UHD-ASM. Time to create and interpret the UHD-ASM was 20 ± 11 min. For every AAF, the entire circuit was identified. Thirty (97%) were macroreentry. AAF cycle length was 267 ± 49 ms, and the circuit length was 138 ± 38 mm (range 35-187). Macroreentry atrial flutters took varied pathways, but each had an area of slow conduction (ASC) averaging 16 ± 6 mm (range 6-29) in length. Entrainment was not utilized. We targeted the ASC and ablation terminated AAF directly in 19/31 (61.3%) and altered AAF activation in 7/31 (22.6%), all of which terminated directly with additional mapping/ablation. AAF degenerated to atrial fibrillation in 2/31 (6.5%) with RF and could not be reinduced after ASC ablation. Median time from initial ablation to AAF termination was 64 s. Thus, 28/31 (90.3%) terminated with RF energy and/or could not be reinduced after ASC ablation. At 1 year of follow-up, 77% were free of atrial tachycardia or atrial flutter and 61% were free of all atrial arrhythmias. CONCLUSIONS: Using rapidly acquired UHD-ASM, the entire AAF circuit as well as the target ASC could be identified. Most AAF were left atrial macroreentry. Ablation of the ASC or microreentry focuses directly terminated or eliminated AAF in 90.3% without the need for entrainment mapping.
No takes yet. Share an insight, caveat, or question.
Winkle et al. (2016) conducted an observational in Atypical atrial flutter (n=23). Ultra high density-activation sequence mapping (UHD-ASM) guided ablation was evaluated on Acute termination or elimination of atypical atrial flutter. Ultra high density-activation sequence mapping guided ablation directly terminated or eliminated atypical atrial flutter in 90.3% of arrhythmias.