Why the study?
Do chest leads improve the detection of S-T interval deviations in patients with coronary thrombosis compared to standard leads?
Do chest leads improve the detection of S-T interval deviations in patients with coronary thrombosis compared to standard leads?
This historical text highlights the early recognition of chest leads (lead IV) in detecting coronary thrombosis when standard limb leads appear normal.
Answers are grounded in this paper and cite their sources.
May aid ST-deviation detection in coronary thrombosis when standard leads are normal; extends early ECG observations but leaves open contemporary validation.
Interest in the use of chest leads in the diagnosis of coronary thrombosis was stimulated by Wolferth and Wood.¹In a patient with normal standard leads with a clinical picture of coronary thrombosis, they found a striking abnormal deviation of the S-T interval from the isoelectric line in tracings taken with electrodes over the anterior and posterior surfaces of the chest. A second patient showed only a minor deviation from the normal in lead I and a more pronounced deviation in the chest lead, or lead IV. These changes they also found in experimentally produced occlusion of the coronary arteries.² They state that "if conclusions are to be drawn from minor variations in the contour of the tracings in lead IV, the relation of electrodes to the heart should be kept constant. We paid no attention to minor variations in the position of the electrodes and have not
No takes yet. Share an insight, caveat, or question.
Arthur Hoffman (1933) studied this question.