Key result
High-power short-duration ablation reaches ~10°C higher tissue temperatures than standard ablation, achieving lethal temperatures faster.
Why the study?
Actual in vivo tissue temperatures and the safety profile during high-power short-duration ablation of AF have not been clarified.
Does 50 W high-power short-duration ablation compared to 30 W standard ablation affect tissue temperatures and lesion transmurality in an animal model?
Does 50 W high-power short-duration ablation compared to 30 W standard ablation affect tissue temperatures and lesion transmurality in an animal model?
In an animal model, AI-guided HPSD ablation achieved higher tissue temperatures and greater transmurality than standard ablation without increasing esophageal injury rates.
Answers are grounded in this paper and cite their sources.
Animal data on HPSD temperatures should not change practice; leaves open whether advantages translate to human lesion durability or safety.
BACKGROUND: Actual in vivo tissue temperatures and the safety profile during high-power short-duration (HPSD) ablation of atrial fibrillation have not been clarified. METHODS: We conducted an animal study in which, after a right thoracotomy, we implanted 6-8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We recorded tissue temperatures during a 50 W-HPSD ablation and 30 W-standard ablation targeting an ablation index (AI) of 400 (5-15 g contact force). RESULTS: Maximum tissue temperatures reached with HSPD ablation were significantly higher than that reached with standard ablation (62.7 ± 12.5 vs. 52.7 ± 11.4°C, p = 0.033) and correlated inversely with the distance between the catheter tip and thermocouple, regardless of the power settings (HPSD: r = -0.71; standard: r = -0.64). Achievement of lethal temperatures (≥50°C) was within 7.6 ± 3.6 and 12.1 ± 4.1 s after HPSD and standard ablation, respectively (p = 0.003), and was best predicted at cutoff points of 5.2 and 4.4 mm, respectively. All HPSD ablation lesions were transmural, but 19.2% of the standard ablation lesions were not (p = 0.011). There was no difference between HPSD and standard ablation regarding the esophageal injury rate (30% vs. 33.3%, p > 0.99), with the injury appearing to be related to the short distance from the catheter tip. CONCLUSIONS: Actual tissue temperatures reached with AI-guided HPSD ablation appeared to be higher with a greater distance between the catheter tip and target tissue than those with standard ablation. HPSD ablation for <7 s may help prevent collateral tissue injury when ablating within a close distance.
No takes yet. Share an insight, caveat, or question.
Otsuka et al. (2021) studied Atrial fibrillation. High-power short-duration (HPSD) ablation vs. Standard ablation (30 W targeting an ablation index of 400) was evaluated on Maximum tissue temperatures (p=0.033). High-power short-duration ablation reached higher maximum tissue temperatures than standard ablation and achieved lethal temperatures faster.