This is the authors' abstract. We don't add key points for this paper.
A dynamic hysteresis control of the buck converter for achieving high slew-rate response to disturbances is proposed. The hysteresis band is derived from the output capacitor current that predicts the output voltage magnitude after a hypothesized switching action. Four switching criteria are formulated to dictate the state of the main switch. The output voltage can revert to the steady state in two switching actions after a large-signal disturbance. The technique is verified with the experimental results of a 50 W buck converter.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Leung et al. (2005) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: